BLOWER
FAN
FILTER GRILL
ASSEMBLY
P/N 41644366
OUTER GRILL HALF
EP006058
Removing Filter Element
REPLACING FUSES
As stated in the Drive Characteristics section of this manual, two fuses and two spare fuses are integrated into the power receptacle on the rear panel of the LF 6600 (refer to the figure below). If the drive will not power up, one or both of the fuses may have blown.
To replace a blown fuse with a spare fuse:
1)Set the drive's AC power switch to the OFF ( O ) position and remove the AC power cord.
2)Insert a small,
3)Gently pry the fuse holder open. Slide the fuse holder out of the receptacle and visually inspect the active fuse to determine if it is blown. If the active fuse is blown, proceed to step 4); otherwise, proceed to 5).
4)Remove the active fuse and discard it. Remove the spare fuse from its storage location and insert the fuse between the fuse housing and the retaining clip.
5)
6)Apply power to the unit (refer to the Power - On Procedure).
7)If power is not restored, check the other fuse.
PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual Page 98