Configuration Files

Network Monitoring <netMon/>

Polycom recommends that you do not change these values.

This configuration attribute is defined as follows:

Attribute

Permitted

Default

Values

 

 

 

tcpIpApp.netMon.enabled

0, 1

1

 

 

 

tcpIpApp.netMon.period

1 to 86400

30

 

 

 

Time Synchronization <sntp/>

The following table describes the parameters used to set up time synchronization and daylight savings time. The defaults shown will enable daylight savings time (DST) for North America.

Daylight savings defaults:

Do not use fixed day, use first or last day of week in the month.

Start DST on the second Sunday in March at 2 am.

Stop DST on the first Sunday in November at 2 am.

 

Permitted

 

 

Attribute

Values

Default

Interpretation

 

 

 

 

tcpIpApp.sntp.resyncPeriod

positive

86400 (24

Time in seconds between

 

integer

hours)

Simple Network Time

 

 

 

Protocol (SNTP) re-syncs.

 

 

 

 

tcpIpApp.sntp.address

valid host

clock

Address of the SNTP

 

name or IP

 

server.

 

address

 

 

 

 

 

 

A - 51

Page 163
Image 163
Polycom SIP 2.2.2 manual This configuration attribute is defined as follows, Attribute Permitted Default Values