Configuration Files

 

 

 

 

 

 

 

 

 

Permitted

 

 

Attribute

Values

Default

Interpretation

voice.vad.signalAnnex

0, 1

Null

If set to 1 and voice.vadEnable is set to 1, Annex B is

B

 

 

used. A new line can be added to SDP depending on the

 

 

 

setting of this parameter and the voice.vadEnable

 

 

 

parameter.

 

 

 

If voice.vadEnable is set to 1, add attribute line

 

 

 

a=fmtp:18 annexb="yes" below a=rtpmap… attribute

 

 

 

line (where '18' could be replaced by another

 

 

 

payload).

 

 

 

If voice.vadEnable is set to 0, add attribute line

 

 

 

a=fmtp:18 annexb="no" below a=rtpmap… attribute

 

 

 

line (where '18' could be replaced by another

 

 

 

payload).

 

 

 

If set to 0 or Null, there is no change to SDP.

 

 

 

 

Quality Monitoring <quality monitoring/>

This attribute includes:

Central Report Collector <collector/>

Alert Reports <alert/>

Server <server/>

RTCP-XR <rtcpxr/>

Central Report Collector <collector/>

This configuration attribute is defined as follows:

Attribute

Permitted

Default

Interpretation

Values

 

 

 

 

voice.qualityMonitoring.collector.enable.pe

0, 1

0

Enables generation of periodic

riodic

 

 

quality reports throughout a call.

 

 

 

 

voice.qualityMonitoring.collector.enable.se

0, 1

0

Enables generation of a quality

ssion

 

 

report at the end of each call.

 

 

 

 

A - 47

Page 165