Configuration Files

 

 

 

 

 

 

 

 

 

 

Attribute

Permitted Values

 

Default

Interpretation

 

 

 

 

 

mb.idleDisplay.refresh

0 or an integer > 5

 

0

The period in seconds between refreshes of the

 

 

 

 

idle display Microbrowser's content. If set to 0,

 

 

 

 

the idle display Microbrowser is not refreshed.

 

 

 

 

The minimum refresh period is 5 seconds

 

 

 

 

(values from 1 to 4 are ignored, and 5 is used).

 

 

 

 

Note: If an HTTP Refresh header is detected, it

 

 

 

 

will be respected, even if this parameter is set to

 

 

 

 

0. The refresh parameter will be respected only

 

 

 

 

in the event that a refresh fails. Once a refresh is

 

 

 

 

successful, the value in the HTTP refresh

 

 

 

 

header, if available, will be used.

 

 

 

 

 

Main Browser <main/>

 

 

This setting controls the home page used by the Microbrowser when that

 

function is selected.

 

 

 

 

 

 

Attribute

Permitted Values

 

Default

Interpretation

 

 

 

 

 

mb.main.home

Any fully formed valid

 

Null

URL used for Microbrowser home page. If blank,

 

HTTP URL. Length

 

 

the browser will notify the user that a blank

 

up to 255 characters.

 

 

home-page was used.

 

 

 

 

For example:

 

 

 

 

http://www.example.com/xhtml/frontpage.cgi?pa

 

 

 

 

ge=home.

 

 

 

 

 

mb.main.statusbar

0, 1

 

Null

Flag to determine whether or not to turn off

 

 

 

 

display of status messages.

 

 

 

 

If set to 1, the display of the status bar is

 

 

 

 

enabled.

 

 

 

 

If set to 0, or Null, the display of the status bar is

 

 

 

 

disabled.

 

 

 

 

 

mb.main.idleTimeout

0 - 600, seconds

 

Null

Timeout for the interactive browser. If the

 

 

 

 

interactive browser remains idle for a defined

 

 

 

 

period of time, the phone should return to the

 

 

 

 

idle browser.

 

 

 

 

If set to 0, there is no timeout.

 

 

 

 

If set to Null, the value from up.idleTimeout is

 

 

 

 

used. Refer to User Preferences <up/> on page

 

 

 

 

A-23. If mb.main.idleTimeout and

 

 

 

 

up.idleTimeout are Null, the timeout is 20

 

 

 

 

seconds.

 

 

 

 

If set to value greater than 0 and less than 600,

 

 

 

 

the timeout is for that number of seconds.

 

 

 

 

 

A - 87

Page 205
Image 205