Chapter 4 Maintenance Schedules

Tech Service Replacement Schedule

Each time a service technician completes a level of preventive maintenance, he or she must reset the service level page count by selecting the Technician Service option on the Maintenance menu. This removes the maintenance error message.

The following actions should be performed by a service technician after the specified number of letter size pages (4% coverage) have been printed.

Item

Part #

Frequency

Action

Service

(Pages)

Level

 

 

 

 

 

 

 

 

Main charger

705741-001

300,000

Replace

D

 

 

 

 

 

Precharger

705742-001

300,000

Replace

D

 

 

 

 

 

Transfer charger

705742-001

300,000

Replace

D

 

 

 

 

 

Smoke filter

703540-001

300,000

Replace

D

 

 

 

 

 

Flash power supply filter

n/a

300,000

Clean

D

 

 

 

 

 

LED air filter

703543-001

600,000

Clean

E

 

 

 

 

 

Lamp housing filter

202838-001

600,000

Clean

E

 

 

 

 

 

Cleaning unit

705740-001

600,000

Replace

E

 

 

See Note 1

 

 

 

 

 

 

 

Transporting belt-3

703531-035

600,000

Replace

E

 

 

 

 

 

Xenon lamp

703541-001

900,000

Replace

F

 

 

 

 

 

Main charger

705741-001

1,200,000

Replace

G

 

 

 

 

 

Precharger

705742-001

1,200,000

Replace

G

 

 

 

 

 

Transfer charger

705743-001

1,200,000

Replace

G

 

 

 

 

 

Cleaning unit

705740-001

1,200,000

Replace

G

 

 

See Note 1

 

 

 

 

 

 

 

Lamp housing filter

202838-001

2,400,000

Replace

H

 

 

 

 

 

92

Page 92
Image 92
Printronix L5535 manual Tech Service Replacement Schedule, Frequency Action Service Pages