Chapter 4 Maintenance Schedules
Tech Service Replacement Schedule
Each time a service technician completes a level of preventive maintenance, he or she must reset the service level page count by selecting the Technician Service option on the Maintenance menu. This removes the maintenance error message.
The following actions should be performed by a service technician after the specified number of letter size pages (4% coverage) have been printed.
Item | Part # | Frequency | Action | Service | |
(Pages) | Level | ||||
|
|
| |||
|
|
|
|
| |
Main charger | 300,000 | Replace | D | ||
|
|
|
|
| |
Precharger | 300,000 | Replace | D | ||
|
|
|
|
| |
Transfer charger | 300,000 | Replace | D | ||
|
|
|
|
| |
Smoke filter | 300,000 | Replace | D | ||
|
|
|
|
| |
Flash power supply filter | n/a | 300,000 | Clean | D | |
|
|
|
|
| |
LED air filter | 600,000 | Clean | E | ||
|
|
|
|
| |
Lamp housing filter | 600,000 | Clean | E | ||
|
|
|
|
| |
Cleaning unit | 600,000 | Replace | E | ||
|
| See Note 1 |
|
| |
|
|
|
|
| |
Transporting | 600,000 | Replace | E | ||
|
|
|
|
| |
Xenon lamp | 900,000 | Replace | F | ||
|
|
|
|
| |
Main charger | 1,200,000 | Replace | G | ||
|
|
|
|
| |
Precharger | 1,200,000 | Replace | G | ||
|
|
|
|
| |
Transfer charger | 1,200,000 | Replace | G | ||
|
|
|
|
| |
Cleaning unit | 1,200,000 | Replace | G | ||
|
| See Note 1 |
|
| |
|
|
|
|
| |
Lamp housing filter | 2,400,000 | Replace | H | ||
|
|
|
|
|