Chapter 4 Maintenance Tools
A service level includes the levels that precede it. For example, at 150,000 pages, you should perform Level B and Level A service. At 900,000 pages, your service provider should perform Level F, Level E, and Level D service.
Note that this condition will not cause the printer to stop printing. When one of the above messages appears, you should perform the appropriate scheduled maintenance or call your
Clearing Service Level Messages
Once you have performed a level of service, you must clear the page count for that service level. Note that when you clear a higher service level, the levels that precede it are also cleared. For example, clearing level C also clears levels A and B.
To clear a service level (level A, for example), select the Maintenance menu from the control panel, select the User Maint option, then select “Clear Level A” by pressing ENTER.