Troubleshooting
| Call “REVIEW”( /* 420 30 */ | |
| Source(), | |
Nodes | Special(), | |
copied from | Destination(), | |
another | Branch(, Display “SCAN” ) ), | |
application | ||
Pasting can cause the Branch line to remain blank or to have invalid Links. | ||
| ||
| To avoid this problem, do not edit files manually. Always rely on PPG to cre- | |
| ate and edit the application files. | |
|
| |
Extra blank |
| |
lines at the | Place the cursor at the end of the file. Delete any extraneous characters | |
end of the | after the final ‘)’ character. | |
file |
| |
|
|
If a few seconds pass with no messages, PPG was unable to make a connection with the portable
•Select a different serial port by selecting Options > Settings. Then select the File > Program the Portable to try again.
•Make sure that the cable is firmly connected at both ends.
•Try resetting the PT40 by pressing <CLR>+<ENT> while reloading the battery.
•If you loaded a different program into your portable since download- ing the sample program earlier, the portable may not be set to allow serial input, or the serial parameters may not be set correctly. In this case, scan the following bar code or select options in the portable to prepare it for downloading.
*/ . *