3 – Managing Fabrics

Zoning a Fabric

 

 

 

 

3.4.1.5

Zoning Configuration

Note the following SANbox2 zoning configuration concepts:

Orphan zones are allowed.

You can not edit an active zone set.

The three types of zones are Soft, VPF, and ACL.

Aliases are allowed.

The zoning limits for a fabric are:

Maximum number of zonesets is 256

Maximum number of zones is 256

Maximum number of aliases is 256

Maximum number of members per zone is 2000

Maximum number of members per aliases is 2000

Maximum total number of members is 2000

The entire zoning database can be saved to either temporary or permanent memory.

You can set the zoning configuration parameters using SANbox Manager or the Set Zoning Config command. Refer to ”Using the Zoning Config Window” on page 3-15for information about zoning configuration using SANbox Manager. Refer to ”Set Config Command” on page A-24for information about the Set Config command.

The following parameters make up the zoning configuration:

Auto Save

Merge Mode

Default Visibility

59022-03 D