Qualstar 501440 Rev. G operation manual FCO Type a Installation

Models: 501440 Rev. G

1 89
Download 89 pages 10.76 Kb
Page 19
Image 19

8.Connect the AUXPWR cable to the AUXPWR connectors on the Executive PCBA and to the Fibre Channel Option. See Figure 4-7and Figure 4-9.

Executive PCBA

AUXPWR Cable

SERIAL Ribbon Cable

Fibre Channel Option

Figure 4-7 Executive PCBA and Fibre Channel Option (Executive III PCBA Shown)

9.The FCO’s SERIAL ribbon cable will connect to differently named connectors on the Executive PCBA depending on which version of Executive PCBA is installed in the library. Executive III PCBA’s will have part number 501387-printed on them and Executive IV boards will have part number 501447- on them. Refer to Figure 4-8to determine which version of Executive PCBA the FCO is being con- nected to.

4-6

FCO Type A Installation

501440 Rev. G

Page 19
Image 19
Qualstar 501440 Rev. G operation manual FCO Type a Installation