Attach the power cord to the FCO and then push the power switch to the on position. Apply power to the TLS library. During initialization, the library will reposition the cartridge handler and tape magazine carrousel. The tape drives and magazines will be scanned to inventory the contents of the library. The third line of the LCD displays the status of these operations.

If the Fibre Channel Option (FCO) is enabled and busy, it will also display status in- formation on the third line of the LCD. If there is more than one message to be dis- played, they will cycle at one-second intervals. Table 4-2shows the possible messages that can appear while the FCO is initializing.

Qualstar•••TLS-412180

FC: Please Wait

On single Fibre Channel Option installations, status messages are prefixed with “FC:”.

Status message

Status Condition

 

 

Please Wait

Waiting for Fibre Channel Option to complete restart initialization.

Reading Config

Reading the Fibre Channel Option configuration data.

Checking Config

Checking the Fibre Channel Option configuration.

Setting Config

Setting the Fibre Channel Option configuration.

Controller Reset

Resetting the Fibre Channel Option.

Table 5-4 Possible Fibre Channel Status Messages

If a serial communications error to the Fibre Channel Option is detected, the following warning will be displayed.

Fibre Channel Communications error detected ENTER to continue

Pressing the ENTER key will clear the message.

This warning message can be caused by an incorrectly installed serial cable. If the message reoccurs after checking the cables and clearing the message using the EN- TER key several times, it may require power cycling the library, to reset the FCO. If this problem occurs, please contact the Technical Support department at Qualstar so that corrective action can be taken.

The initialization procedure can take up to several minutes. If the host system is started while FCO status messages are still present, the host may miss seeing the Fi- bre Channel devices because the system is still busy. The host should be instructed to scan for Fibre Channel devices after the FCO has been configured and line three is clear in the TLS Library’s LCD display.

5-10

FCO Type B Installation

501440 Rev. G

Page 37
Image 37
Qualstar 501440 Rev. G operation manual QualstarTLS-412180 FC Please Wait