| When a Message Is Displayed |
|
|
|
|
|
|
|
|
Message | Cause |
| Solution |
|
|
|
|
|
|
| |
Fatal error has | An unrecoverable error | Contact your service representative. |
|
| |
occurred in the | has occurred on the ma- |
|
|
|
|
scanner. | chine. |
|
|
|
|
|
|
|
|
| |
Cannot connect to | An access mask is set. | Contact the network or scanner administrator. |
|
| |
the scanner. |
|
|
|
|
|
Check the network |
|
|
|
|
|
Access Mask set- |
|
|
|
|
|
tings in User |
|
|
|
|
|
Tools. |
|
|
|
|
|
|
|
|
|
| |
Scanner is not | The ADF cover is open. | Check whether the ADF cover is closed. |
|
| |
ready. Check the |
|
|
|
|
|
scanner and the |
|
|
|
|
|
options. |
|
|
|
|
|
|
|
|
|
| |
Insufficient mem- | Scanner memory is in- | • Reset the scan size. |
|
| |
ory. Reduce the | sufficient. | • | Lower the resolution. |
|
|
scanning area. |
| • | Set with no compression. See the |
| 5 |
|
|
| |||
|
|
| TWAIN Driver Help. |
|
|
|
| The problem may be due to the follow- |
|
| |
|
| ing cause: |
|
| |
|
| • “The Relationship between the Reso- |
|
| |
|
|
| lution and the Scanning Area” chart |
|
|
|
|
| in Help for halftone scanning might |
|
|
|
|
| not always apply. Scanning cannot |
|
|
|
|
| be performed if large values are set |
|
|
|
|
| for brightness when using halftone |
|
|
|
|
| or high resolution. |
|
|
|
|
|
|
| |
Insufficient mem- | When a paper misfeed | After the misfed paper has been re- |
|
| |
ory. Reduce the | occurs in the machine | moved, proceed with scanning. |
|
| |
scanning area. | during printing, scanning |
|
|
|
|
| cannot be performed. |
|
|
|
|
|
|
|
|
| |
Cannot find "XXX" | • The main power | • Check whether the main power |
|
| |
scanner used for | switch of the previ- |
| switch of the scanner used for the |
|
|
the previous | ously used scanner is |
| previous scan is turned off. |
|
|
scan. "YYY" will | not set to “On”. | • Check whether the scanner used for |
|
| |
• The machine is not |
|
| |||
be used instead. |
| the previous scan is connected to the |
|
| |
(“XXX” and “YYY” indi- | connected to the net- |
| network correctly. |
|
|
work correctly. | • Deactivate the personal firewall of |
|
| ||
cate scanner names.) |
|
| |||
|
|
| |||
|
|
| the client computer. |
|
|
|
| • Use an application such as telnet to |
|
| |
|
|
| make sure SNMPv1 or SNMPv2 is |
|
|
|
|
| set as the machine’s protocol. See |
|
|
|
|
| “Network Settings”, General Set- |
|
|
|
|
| tings Guide and “Using telnet”, Net- |
|
|
|
|
| work Guide. |
|
|
|
| • Select the scanner used for the previ- |
|
| |
|
|
| ous scan. |
|
|
|
|
|
|
|
|
71