Rinnai E75CP, E110CP, E75CN Testing for gas leaks, Testing the Ignition Safety shut off device

Models: E75CP E110CN E75CN E110CP

1 108
Download 108 pages 9.51 Kb
Page 51
Image 51
12.1 Testing for gas leaks

12.1 Testing for gas leaks

!

!

WARNING

DANGER

Prior to start-up of the boiler you must check the external tightness of the gas supply valve and confirm this in the start-up report.

-Cover endangered positions before leak testing.

-Do not spray the leak testing agent onto cables, plugs, electrical connec- tion lines or electronic circuit boards. Do not allow it to drip onto them either.

Leaks may be caused to pipes and screw connections during commissioning and maintenance activities.

-Carry out a proper leak test.

-Only use approved leak detection agents for leak detection.

-Disconnect the heating system from the power supply.

-Check the exterior tightness of new conduit sections up to and including the direct sealing point on the gas burner fitting. The maximum test pressure allowed on the input of the gas burner fitting is 14 inch W.C. (35mbar).

12.2 Testing the Ignition Safety shut off device

!WARNING

- Switch off system using the Central Heating button and the DHW button

 

- Disconnect the plug and socket connection of the ionization cable.

 

- Switch on the sytem using the Central Heating button and the DHW button.

 

- Press the MODE-button for 5 seconds.

 

 

- The display will show COdE followed by an arbitrary number;

 

-

Select by means of the

or the

button the code C123;

Series-E

-

Press the MODE-button until SERV is shown;

- Press the Store-button to confirm the code (code blinks 1 x);

 

- Press the STEP-button once until 1 is shown;

Rinnai

 

 

alternately 1 and OFF will be shown.

 

Instructions

-

Press the

button once;

 

 

 

 

 

 

Check if the boiler does one start-up attempt and four restart attampts.

 

 

After the last start-up attempt, the boiler will lock out. The gas valve is shut off.

Servicing&

 

The E02 code is blinking in the display.

 

 

 

 

- Connect the plug and socket connection of the ionisation cable.

 

- Press the reset button.

 

 

Installation

Do not touch the inside of the igntion cable while it is disconnected during

- Check if the boiler starts-up.

 

 

 

start up of the boiler.

51

 