Rinnai E110CN, E110CP, E75CN, E75CP user manual 15.2.16Error

Models: E75CP E110CN E75CN E110CP

1 108
Download 108 pages 9.51 Kb
Page 82
Image 82
15.2.16Error 32

Installation & Servicing Instructions Rinnai E-Series

15.2.16Error 32

shut down of return sensor T2

check the data in Error mode

boiler data during error

1

error

 

 

2

operational

 

 

 

status

 

 

3

supply temp.

 

 

4

return temp.

 

 

5

kW burner

 

 

6

% pump

1

= 32

 

 

 

2

= 00

 

 

 

 

 

 

3

= xx*

 

 

 

4

= 230

 

 

 

5

= 00

 

 

 

6

= xx*

 

 

 

*= variable value

check the wiring

check the wiring for the sensor

the wiring is OK but the error is repeated

remove the plug from the return sensor as a result of which Error 37 occurs

replace the

sensor