Rinnai E110CP, E75CN, E110CN, E75CP user manual 15.2.18Error

Models: E75CP E110CN E75CN E110CP

1 108
Download 108 pages 9.51 Kb
Page 84
Image 84
15.2.18Error 37

Installation & Servicing Instructions Rinnai E-Series

15.2.18Error 37

contact for return sensor T2 open

 

check the data

 

 

 

in Error mode

 

 

 

 

 

boiler data during error

 

 

 

 

 

 

 

 

1

error

 

 

2

operational

 

 

 

status

 

 

3

supply temp.

 

 

4

return temp.

 

 

5

kW burner

 

 

6

% pump

1

= 37

 

 

 

2

= 00

 

 

 

 

 

 

3

= xx*

 

 

 

4

= -22

 

 

 

5

= 00

 

 

 

6

= xx*

 

 

 

*= variable value

check the wiring

check the wiring for the sensor to make sure it is not broken

the wiring is OK but the error is repeated

connect the wiring from the return sensor with one another as a result of which Error 32 occurs

replace the

sensor

84

Page 84
Image 84
Rinnai E110CP, E75CN, E110CN, E75CP user manual 15.2.18Error