Rinnai E75CN insufficient quantity of hot water, 16.4Insufficient quantity of hot water, mixed up

Models: E75CP E110CN E75CN E110CP

1 108
Download 108 pages 9.51 Kb
Page 89
Image 89
16.4Insufficient quantity of hot water

16.4Insufficient quantity of hot water

insufficient quantity of hot water

hot and cold water

connection to the boiler

mixed up

check left = hot, right = cold

incorrect flow reducing

valve

check for the type and for contamination, if necessary replace and/or clean.

in the absence of

positive results

check for lime scale

lime scale in the plate

heat exchanger

if necessary descale or replace

Installation & Servicing Instructions Rinnai E-Series

89

Page 89
Image 89