5.1Requirements for the installation room

! DANGER

- The room where the boiler will be installed must always be frost free.

- Do not store or use gasoline or other flammable vapors and liquids in the

 

vicinity of this or any other appliance.

 

- Never use or store any chlorinated detergents or halogenated hydrocarbons

 

(e.g. in spraycans, solvents and detergents, paints, adhesives) in proximity

 

of the boiler.

 

- The boiler must be installed in such a way that it is protected from water

 

(dripping, spraying, rain, etc.) during boiler operation and service (circulator

 

replacement, condensate trap, control replacement, etc.)

 

- This boiler is for intended for indoor installations only.

 

 

 

 

 

Products to avoid present in boiler room

 

 

 

and/or around combustion air intake

 

 

 

Spray cans containing chloro-/fluorcarbons

 

 

 

Ammonium and/or ammonium solutions

 

 

Permanent wave solutions

 

 

Chlorinated waxes and/or cleaners

 

 

Swimming pool chemicals based on chlorine

 

 

Calcium chloride used for thawing

 

 

Sodium chloride used for water softening

 

 

Refrigerant leaks

 

 

Paint or varnish removers

 

 

Hydrochloric acid/muriatic acid

 

 

Cements and glues

 

 

Antistatic fabric softeners used in clothes dryers

 

 

Chlorine-type bleaches, detergents, and cleaning solvents

 

 

found in household laundry rooms

 

 

Adhesives used to fasten building products and

 

 

other similar products

 

 

Areas likely to have contaminants

 

 

 

Dry cleaning/laundry areas and establishments

 

 

 

Swimming pools

 

 

Metal fabrication plants

 

 

Beauty shops

 

 

Refrigeration repair shops

 

 

Photo processing plants

 

 

Auto body shops

 

 

Plastic manufacturing plants

 

 

Furniture refinishing areas and establishments

 

 

New building construction

 

 

Remodeling areas

 

 

Garages with workshops