Chapter 4 Using Link
Check the configuration of the Phone System.
Before connecting to the telephone system, you have to set up the connection parameters within the system; the method used depends on the connection mode. (SIM, Serial, or TCP/IP).
Telephone settings for a serial Link connection
yFor SIM or Serial connection mode,
Be sure that the MMC 804 settings of DCS Key telephone PBX system are as follows:
Sys IOPort | 2 | * (1) |
Service | * (2) | |
BAUD RATE | 9600 or 19200 | * (3) |
CHAR LENGTH | 8 |
|
PARITY | NONE |
|
STOP BIT | 1 |
|
RETRY COUNT | 5 |
|
WAIT TIME | 03000 msec. |
|
Note | The “*” means that you can change the value as needed. |
| The change of (1) entry depends on the number of ports provided by Samsung Key telephone |
| system. |
| The (2) entry can have one of CTI, |
| The baud rate of (3) entry depends on that of Samsung Key telephone system. The baud rate of |
| Link shall be specified based on the value of (3) entry. |
|
|
Telephone settings for an IP Link connection
yFor TCP/IP connections,
Be sure that the IP address of the telephone system has been specified in the MMC 830. This IP address shall be the same as in the communication environment of Link.
Note | Some of the DCS Key telephone systems that support TCP/IP connections cannot transfer SMCR |
| / UCD information to the TCP/IP port. When interworking with these systems, the Link does not |
| transfer the SMDR / UCD message. |
|
|
Connecting to a telephone system
After setting the parameters above, click on the [CONNECT] button of Link
【 】, and proceed to the connection process of PBX system.
Note | In you intend to use the Link in the user management mode, add the user information before |
| proceeding to the connection process of PBX system. For details of user management, see later in |
| this chapter. |
|
|