Trouble Diagnosis

3. W-2WAY ECO-i Alarm Codes

W-2WAY ECO-i Trouble Diagnosis

Alarm code

 

 

Alarm meaning

Page

 

 

 

 

E06

Outdoor unit failed to receive serial communication signals from indoor unit.

3-6

E12

Automatic address setting start is prohibited.

3-6

E15

Automatic address setting alarm (too few units)

3-6

E16

Automatic address setting alarm (too many units)

3-7

E20

No indoor units at automatic address setting.

3-7

E24

Outdoor unit (INV) failed to receive communications from another outdoor

3-7

 

unit (constant-speed).

 

 

 

 

 

 

 

 

E25

Outdoor unit address setting failure (duplication)

3-8

E26

Mismatch in outdoor unit quantity

3-8

E29

Outdoor unit failed to receive communication from relay control unit

3-8

 

 

 

 

F04

Compressor 1 discharge temperature sensor trouble

3-9

F05

Compressor 2 discharge temperature sensor trouble

3-9

 

 

 

 

F22

Compressor 3 discharge temperature sensor trouble

3-9

F06

Gas temperature sensor trouble at outdoor heat exchanger 1 (In)

3-10

F07

Liquid temperature sensor trouble at outdoor heat exchanger 1 (Out)

3-10

F08

Outdoor air temperature sensor trouble

3-11

F12

Compressor intake temperature sensor trouble

3-11

F16

High-pressure sensor trouble

3-11

F17

Low-pressure sensor trouble

3-11

F23

Gas temperature sensor trouble at outdoor heat exchanger 2 (In)

3-10

F24

Liquid temperature sensor trouble at outdoor heat exchanger 2 (Out)

3-10

F31

Outdoor unit non-volatile memory (EEPROM) trouble

3-12

 

 

 

 

H03

Compressor CT sensor disconnected or short-circuit.

3-12

H11

Constant speed compressor 2 overcurrent alarm

3-14

H12

Constant speed compressor 2 lock current alarm

3-14

H05

Compressor 1 discharge temperature sensor disconnected

3-15

H06

Low-pressure trouble in refrigerant circuit.

3-13

H13

Compressor 2 CT sensor disconnected or short-circuit

3-15

H15

Compressor 2 discharge temperature sensor disconnected

3-15

H21

Compressor 3 overcurrent alarm

3-14

H22

Compressor 3 lock current alarm

3-14

H23

Compressor 3 CT sensor disconnected or short-circuit

3-15

H25

Compressor 3 discharge temperature sensor disconnected

3-15

H31

HIC trouble alarm

 

3-16

 

 

 

 

L04

Outdoor unit address duplication

3-16

L05

Duplicated indoor unit priority (alarm at priority indoor units)

3-16

L06

Duplicated indoor unit priority (alarm at non-priority indoor units)

3-17

L10

Outdoor unit capacity not set

3-17

L17

Outdoor unit model mismatch

3-17

L18

4-way valve operation failure.

3-17

 

 

 

 

P03

Compressor 1 discharge temperature trouble

3-18

P04

High-pressure switch activated

3-19

P05

Reverse phase (or missing phase) detected, capacity mismatch

3-20

P16

Compressor 1 overcurrent

 

3-20

P17

Compressor 2 discharge temp trouble

3-18

P18

Compressor 3 discharge temp trouble

3-18

P22

Fan motor trouble

 

3-21

P26

Inverter compressor high-frequency overcurrent alarm

3-21

P29

Inverter compressor missing phase or lock alarm

3-21

 

 

 

 

 

Blinking on the wired remote controller

 

CHECK blinking (1)

3-22

 

CHECK blinking (2)

3-23

 

 

 

3-5

1

2

3

4

5

6

7

8

Page 67
Image 67
Sanyo UHX0752, UHX2452, UHX1252, UHX3652, UHX1852, THX2452, THX1252, THX1852 2WAY ECO-i Alarm Codes, Alarm code Alarm meaning