| USER SETTINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Program |
| Setting codes |
|
|
|
|
|
Program name | (factory default |
|
| Explanation |
|
| |
number | setting appears |
|
|
|
| ||
|
|
|
|
|
| ||
|
| in bold) |
|
|
|
|
|
|
|
| • | This is used to adjust the |
|
| |
|
| 1: SPF/RSPF |
| exposure level. |
|
| |
|
| (Adjustment to | • | The automatic exposure level can |
|
| |
|
| 5 levels is |
| be adjusted separately for the |
|
| |
|
| possible.) |
| document glass and the RSPF. |
|
| |
19 | AE LEVEL ADJUST | 2: DOCUMENT |
|
|
| ||
• For the procedure for adjusting |
|
| |||||
|
| GLASS |
|
| |||
|
|
| the exposure and guidelines |
|
| ||
|
| (Adjustment to |
|
|
| ||
|
| 5 levels is |
| for numeric values, see page |
|
| |
|
| possible.) |
| 24. The factory default setting |
|
| |
|
|
|
| for the exposure level is center. |
|
| |
|
|
|
|
|
|
|
|
|
| 1: AMERICAN |
|
|
|
|
|
|
| ENGLISH | • | This is used to set the |
|
| |
20 | LANGUAGE | 2: ENGLISH |
|
| |||
| language used in the display. |
|
| ||||
|
| 3: FRENCH |
|
|
| ||
|
|
|
|
|
|
| |
|
| 4: SPANISH |
|
|
|
|
|
|
|
|
|
|
|
| |
21 | RESET FACTORY | 1: YES | • | This is used to return all settings |
|
| |
2: NO |
| to the factory default settings. |
|
| |||
|
|
|
|
| |||
|
|
|
|
|
|
| |
22 | SORT AUTO | 1: ON | • | Use this setting to enable or |
|
| |
SELECT | 2: OFF |
| disable sort auto select mode. |
|
| ||
|
|
|
| ||||
|
|
|
|
|
| ||
|
|
| • You can set the operation that |
|
| ||
|
|
|
| takes place if the [START] key |
|
| |
24 | CHECK RSPF | 1: ON |
| ( | ) is pressed when the |
|
|
OPEN | 2: OFF |
| RSPF is not completely closed. |
|
| ||
|
|
|
| ||||
|
|
|
| (For details on the "Check RSPF |
|
| |
|
|
|
| open function", see page 13.) |
|
| |
|
|
|
|
|
|
| |
|
|
| • | Set the allowed paper sizes |
|
| |
|
|
|
| for copying from the bypass |
|
| |
25 | VALID COPY | 1: 8.5x11 |
| tray. When "5.5x8.5" is |
|
| |
WIDTH | 2: 5.5x8.5 |
| selected, a copy of a letter |
|
| ||
|
| 7 | |||||
|
|
| |||||
|
|
|
| size original will only be |
| ||
|
|
|
|
|
| ||
|
|
|
| printed up to invoice size. |
|
| |
|
|
|
|
|
| ||
|
|
| • Select whether copying is only |
|
| ||
28 | LSU SETTING | 1: ON |
| allowed when the polygon |
|
| |
2: OFF |
| motor is rotating, or also when |
|
| |||
|
|
|
|
| |||
|
|
|
| the polygon motor is stopped. |
|
| |
|
|
|
|
|
|
| |
|
|
| • | Set the temperature of the |
|
| |
29 | PAPER TYPE | 1: PLAIN PAPER |
| fusing unit when the bypass |
|
| |
2: HEAVY PAPER |
| tray is used. Normally "PLAIN |
|
| |||
|
|
|
|
| |||
|
|
|
| PAPER" should be selected. |
|
| |
|
|
|
|
|
|
|
|
|
| 1: LIGHTER |
|
|
|
|
|
| DISPLAY | 2: LIGHT | • | Set the contrast of the display. |
|
| |
30 | 3: NORMAL |
|
| ||||
CONTRAST |
|
| |||||
| 4: DARK |
|
|
|
|
| |
|
|
|
|
|
|
| |
|
| 5: DARKER |
|
|
|
|
|
|
|
|
|
|
|
|
|
57