Finding RS-232 Commands in Macros

As stated on page 42, the C4630 SE is capable of serial operation in one direction only, either inbound OR outbound. Placing a single RS-232 command in one macro will automatically configure the C4630 SE for outbound serial operation — the unit will not respond to inbound commands from a connected serial control device.

To allow the C4630 SE to become an inbound serial device that will respond to commands from a connected serial control device you must remove all RS-232 commands from all C4630 SE macros. The System Configuration Report allows you to see every command in every C4630 SE macro, making it easier to delete all RS-232 commands.

As you scroll-through the macros in the System Configuration Report, RS-232 macro commands will appear as shown in Figure 73.

C4630 SE HOME AUDIO SYSTEM

RS-232 Macro

Commands

Figure 73:

System Configuration Report

Showing RS-232 Macro Commands

50

Page 50
Image 50
Sonance C4630 SE Finding RS-232 Commands in Macros, System Configuration Report Showing RS-232 Macro Commands