C4630 SE HOME AUDIO SYSTEM
AUDIO (continued) |
|
Problem | Solution |
No audio in zone | a) Are speakers connected? |
| b) Is zone ON? |
| c) Is zone volume turned up? |
| d) Check zone’s MAXIMUM VOLUME/DEFAULT VOLUME settings in Sonance Control |
| Manager software. |
|
|
No Paging signal in zones. | a) Be sure device’s 12V Page trigger input is connected to C4630 SE’s CONTROL |
| INPUT (see page 16). |
| b) Be sure Page trigger device is outputting 6 – 24V AC/DC. |
| c) In an expanded system (multiple C4630 SEs) be sure the Paging audio source |
| is connected to the PAGE IN jack on the primary C4630SE (see page 17). |
| d) In an expanded system, be sure PAGE IN/OUT jacks are connected between |
| C4630 SEs in an expanded system (see page 17). |
|
|
No audio in zones driven by secondary | a) Be sure the Source Outputs on the primary C4630 SE (the one connected to |
C4630 SEs in an expanded system | the source components) are connected to the Source Inputs on the secondary |
| C4630 SE(s). See page 13. |
| b) Check the Sonance Control Manager Volume Offset settings for sources on |
| secondary C4630 SEs (should be ‘0’.) See page 30. |
|
|
EXTERNAL AMPLIFIERS |
|
Problem | Solution |
Keypad or remote VOLUME UP/DOWN | a) Make sure the specific Zone FIXED/VARIABLE output switch is in the FIXED (IN) |
commands change volume in all sub- | position (see page 13). |
zones when using external multi- | b) Make sure the Zone’s DEFAULT and MAXIMUM VOLUMES are set at their appropriate |
channel amplifier for | maximum volume in Sonance Control Manager software to achieve proper |
expansion | audio level in |
|
|
Keypad or remote VOLUME UP/DOWN | Make sure the specific Zone FIXED/VARIABLE output switch is in the VARIABLE (OUT) |
do not adjust volume when using an | position (see page 13). |
external amplifier. |
|
53