7-1 Head Cleaning

Use the BCT-5CLN Cleaning Cassette to clean the heads.

Read the instructions included with the cleaning cassette carefully, as improper usage can damage the heads.

Follow the procedure below to clean the heads.

1 Insert the cleaning cassette.

2 Press the EJECT button simultaneously with the PLAY button.

Head cleaning starts.

After head cleaning continues for five seconds, the cleaning cassette is automatically ejected.

Notes

When not using the automatic eject method above with the DVW-A500/1 series, be sure to eject the cleaning cassette after cleaning not to damage the heads.

When cleaning the heads of the DVW-500/1 series, perform Step 2 immediately after inserting the cleaning cassette.

If you do not, the cassette will be ejected after two or three seconds and no head cleaning will be done.

Maintenance 7 Chapter

Maintenance 7 Chapter

Chapter 7 Maintenance

7-1