Items Related to Prerolling (400s)

The values enclosed in a box are factory settings.

Item number

Item

Settable range

Function

401

FUNCTION MODE

[0]

[stop]

Selects the operation mode that the VTR changes to after

 

AFTER CUE-UP

1

still

completing a cue up operation.

 

 

 

 

0

: Enters stop mode.

 

 

 

 

1

: Enters still-picture mode (search mode).

 

 

 

 

Note

 

 

 

 

 

When setting the standard constant on the editor and

 

 

 

 

control the unit, set to “0.”

403

AUTOMATIC

[0]

[disable]

Specifies whether IN point is automatically set when the

 

PREROLL

1

enable

PREROLL button is pressed, in the case no IN point has

 

REFERENCE

 

 

been set at the start of a preroll operation.

 

ENTRY

 

 

0

: IN point is not set automatically.

 

 

 

 

1

: IN point is set automatically.

 

 

 

 

 

404

CUEUP BY TC

0

capstan only

The setting of this item is valid only when the [F1] (TIMER

 

 

[1]

[reel/capstan]

SEL) button in the TC menu is set to TC or UBIT.

 

 

 

 

0

: The tape runs with the pinch ON during cue up. (The

 

 

 

 

 

maximum tape speed is ten times normal tape speed.)

 

 

 

 

1

: The tape runs with the pinch OFF state during cue up.

 

 

 

 

 

When the tape nears the cue up point and tape speed

 

 

 

 

 

drops to slow, the pinch turns ON.

 

 

 

 

Select “0” when the tape contains a discontinuity in its

 

 

 

 

time code signal and the part that is prerolled contains the

 

 

 

 

discontinuity. (Prerolling is performed by interpolating the

 

 

 

 

time code preceding the discontinuity using the CTL

 

 

 

 

signals.)

 

 

 

 

 

405

CUEUP BY CTL

[0]

[capstan only]

The setting of this item is valid only when the [F1] (TIMER

 

 

1

reel/capstan

SEL) button in the TC menu is set to CTL.

 

 

 

 

0

: The tape runs with the pinch ON state during cue up.

 

 

 

 

 

(The maximum tape speed is ten times normal tape

 

 

 

 

 

speed.)

 

 

 

 

1

: The tape runs with the pinch OFF state during cue up.

 

 

 

 

 

When the tape nears the cue up point and tape speed

 

 

 

 

 

drops to slow, the pinch turns ONa).

 

 

 

 

Select “0” when editing precision has priority.

a)When this unit is controlled by an editor (BVE-2000/BVE-9100, etc), and the seting is “1”, cue up operations are done at high speed.

Appendix