301

VAR SPEED

[0]

[–1 to +3]

Specifies the variable tape speed range when the variable

 

RANGE FOR

1

–1.15 to +3.45

speed playback is executed by a remote control unit

 

SYNCHRONIZATION

 

 

connected to the REMOTE1 IN (9P) connector.

 

 

 

 

0

: –1 to +3 times normal tape speed

 

 

 

 

1

: –1.15 to +3.45 times normal tape speed

 

 

 

 

Note

 

 

 

 

 

When an editing control unit such as BVE-9000 is

 

 

 

 

connected for DT editing, select “1”.

 

 

 

 

When “1” is selected and the DT playback at a speed

 

 

 

 

exceeding –1 to +3 times nomal tape speed is attempted

 

 

 

 

during analog Betacam playback, the bottom of the picture

 

 

 

 

may partially disappear. This is not a malfunction.

302

CAPSTAN

[0]

[deceleration]

Specifies whether capstan servo is re-locked in

 

RE-LOCKING

1

acceleration

deceleration mode or acceleration mode when the ALT/[F5]

 

DIRECTION

 

(DVW-A500/1 and

(CAP LOCK) button in the HOME menu is set to 4FD

 

 

 

500/1)

(DVW-A500/1 and 500/1) or 4FD or 8FD (DVW-A500P/1

 

 

0

deceleration

and 500P/1) .

 

 

[1]

[acceleration]

0 : Capstan servo re-locks in deceleration mode.

 

 

 

(DVW-A500P/1 and

1 : Capstan servo re-locks in acceleration mode.

 

 

 

500P/1)

 

 

 

 

 

 

 

304

EDIT FIELD

[0]

[1F]

Specifies the timing for the start of editing in an edit mode.

 

SELECT

1

2F

0 : Tape editing starts from field 1 and ends at field 2.

 

 

2

1F/2F

1 : Tape editing starts from field 2 and ends at field 1.

 

 

 

 

2 : Tape editing is carried out according to the timing of

 

 

 

 

commands.

 

 

 

 

 

305

SYNC GRADE

[0]

[accurate]

Specifies the editing accuracy when performing editing in

 

 

1

rough

phase-synchronized mode when the item 004 is set to “0”.

 

 

 

 

0 : Editing accuracy of ±0 frame

 

 

 

 

1 : Editing accuracy of ±1 frame

 

 

 

 

For details on item 004, refer to page A-8.

 

 

 

 

 

306

DMC INITIAL

[00]

[manual]

Specifies the initial tape speed that is set automatically

 

SPEED

01

play

during DMC (Dynamic Motion Control) editing.

 

 

02

still

00 : The initial tape speed is determined by the rotation

 

 

03

+0.03

angle of the search dial.

 

 

04

+0.1

01 : Normal playback speed

 

 

05

+0.2

02 : Tape is stopped.

 

 

06

+0.5

03 to 13 : The initial tape speed is the selected search

 

 

07

+1

speed.

 

 

08

+2

 

 

 

 

09

–0.03

 

 

 

 

10

–0.1

 

 

 

 

11

–0.2

 

 

 

 

12

–0.5

 

 

 

 

13

–1

 

 