Items Related to the Time Code Generator (600s)

The values enclosed in a box are factory settings.

Item number

Item

Settable range

 

Function

601

VITC POSITION

12

 

12 line

 

 

Specifies the line the VITC signal is inserted into.

(DVW-A500/1

SEL-1

I

 

I

 

 

The VITC signal can be inserted in any line from line 12

and 500/1)

 

[16]

 

[16 line]

 

through line 20.

 

 

I

 

I

 

 

 

 

 

 

 

 

Note

 

 

 

20

 

20 line

 

 

 

 

 

 

 

 

VITC can be inserted into two positions through item 601

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and item 602.

 

 

 

 

 

 

 

 

601

VITC POSITION

9

9 line

 

 

Specifies the line the VITC signal is inserted into.

(DVW-A500P/1

SEL-1

I

 

I

 

 

The VITC signal can be inserted in any line from line 9

and 500P/1)

 

[19]

[19 line]

 

 

through line 22.

 

 

I

 

I

 

 

 

 

 

 

 

 

Note

 

 

 

22

22 line

 

 

 

 

 

 

 

 

 

 

VITC can be inserted into two positions through the item

 

 

 

 

 

 

 

601 and item 602.

602

VITC POSITION

12

 

12 line

 

 

Specifies the line the VITC signal is inserted into.

(DVW-A500/1

SEL-2

I

 

I

 

 

The VITC signal can be inserted in any line from line 12

and 500/1)

 

[18]

 

[18 line]

 

through line 20.

 

 

I

 

I

 

 

 

 

 

 

20

 

20 line

 

 

Note

 

 

 

 

 

 

 

 

The VITC can be inserted into two position through item

 

 

 

 

 

 

 

601 and item 602.

 

 

 

 

 

 

 

 

602

VITC POSITION

9

9.322

line

 

Specifies the line the VITC signal is inserted into.

(for DVW-

SEL-2

I

 

I

 

 

The VITC signal can be inserted in any line from line 9

A500P/1 and

 

[21]

 

[21.334 line]

 

through line 22.

500P/1)

 

22

22.335

line

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The VITC can be inserted into two position through item

 

 

 

 

 

 

 

601 and item 602.

 

 

 

 

 

 

 

 

603

ID CODE SET

 

00000000

 

Sets the ID code.

 

 

 

 

I

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

FFFFFFFF

 

 

 

 

 

 

 

 

 

To set the ID code

 

 

 

 

 

 

 

Enter the ID code using the numeric buttons, then press

 

 

 

 

 

 

 

the SET button.

 

 

 

 

 

 

 

 

605

TCG REGEN

[0]

 

 

 

 

Specifies the type of signal to be regenerated when the

 

TC&UB

 

 

 

MODE

1

 

TC

 

 

time code generator is in the regeneration mode (i.e., when

 

 

2

 

UB

 

 

the [F7] (TCG MODE) button in the TC menu is set to regen

 

 

 

 

 

 

 

or when the unit is in automatic edit mode).

 

 

 

 

 

 

 

0 : Both the time code and user bit signals are regenerated.

 

 

 

 

 

 

 

1 : Only the time code signal is regenerated.

 

 

 

 

 

 

 

2 : Only the user bit signal is regenerated.

 

 

 

 

 

 

 

 

 

Appendix