Settings Menu 4 Chapter

4-3 TC Menu

Changing the superimposition position

DVW-A500/1 and 500/1 only

The superimposition position can be moved up to 37 increments (hexadecimal 00 to 24) in the horizontal direction and up to 106 increments (hexadecimal 00 to 6A) in the vertical direction.

DVW-A500P/1 and 500P/1 only

The superimposition position can be moved up to 35 increments (hexadecimal 00 to 22) in the horizontal direction and up to 129 increments (hexadecimal 00 to 81) in the vertical direction.

1,3 2

Changing the superimposition position

1 Press the ALT button and then the [F7] (CHARA H-POS) button to move the superimposition position in the horizontal direction, or the [F8] (CHARA V-POS) button to move it in the vertical direction.

A data entry window appears.

2 Press the G or g button to change the value. You can also use the + or – button.

3 Press the [F7] (CHARA H-POS) or [F8] (CHARA V-POS) button.

The data setting is completed and the data entry window disappears.

Switching to another menu also completes the data setting.

4-3-10 Setting the VITC Insertion Line (VITC POS-1/POS-2)

VITC signals can be inserted at two positions between the 12th line and 20th line (DVW-A500/1 and 500/1) or between the 9th line and 22nd line (DVW-A500P/1 and 500P/1).

1,3 2

Setting the VITC insertion line (VITC POS-1/POS-2)

1 Press the ALT button, then the [F9] (VITC POS-1) button.

A data entry window appears.

2 Press the G or g button to change the value. You can also use the +or – button.

3 Press the [F9] (VITC POS-1) button.

The data setting is completed and the data entry window disappears.

Switching to another menu also completes the data setting.

To place VITC on another position, repeat the procedure above, pressing the [F10] (VITC POS-2) button in Steps 1 and 3 instead of the [F9] (VITC POS-1) button.

4-26Chapter 4 Menu Settings