Appendix

Menu List

Items Related to Remote Interface (200s)

The values enclosed in a box are factory settings.

Item number

Item

Settable range

Function

201

PARA RUN

[0]

[disable]

Specifies whether two or more VTRs run in parallel as

 

 

1

enable

they are synchronized or not.

 

 

 

 

0: Two or more VTRs are not synchronized.

 

 

 

 

1: Two or more VTRs are synchronized.

 

 

 

 

Note

 

 

 

 

 

To synchronized two or more VTRs in parallel, set the

 

 

 

 

item 201 in all VTRs to “1”.

 

 

 

 

 

202

CF FLAG REPLY

[0]

[8F]

Selects the field when the color frame lock is set to “1” in

(DVW-A500P/1

 

1

4F or 8F

the status data that is returned to the REMOTE1-IN (9P)

and 500P/1only)

 

 

 

connector on the connector panel.

 

 

 

 

0: Field 8

 

 

 

 

1: Field 4 or 8

 

 

 

 

208

PROTOCOL FOR

[0]

[SONY 9 pin protocol] Selects the type of the communication protocol for the

 

REMOTE 1

1

ESBUS

REMOTE1 (9P) connector on the connector panel.

 

 

AUTO selection

0: SONY 9 pin protocol

 

 

2

1: EBU-SMPTE bus protocol

 

 

 

 

 

 

 

2: EBU-SMPTE bus and SONY 9 pin protocols are

 

 

 

 

automatically selected.

 

 

 

 

 

209

ES BUS ADDRESS

[8280]

[8280]

Allocates the bus for the ES BUS protocol when it is used

 

 

I

I

as the communication protocol for the REMOTE1

 

 

82FE

82FE

connector.

 

 

8380

8380

 

 

 

 

I

I

 

 

 

 

83FE

83FE

 

 

 

 

8480

8480

 

 

 

 

I

I

 

 

 

 

84FE

84FE

 

 

 

 

I

I

 

 

 

 

I

I

 

 

 

 

FF80

FF80

(Only even data are shown.)

 

 

I

I

 

 

FFFE

FFFE

 

 

A-14Appendix