610

REGEN CONTROL

[0]

 

 

 

Specifies whether the time code signal is automatically

 

auto (assem & insert) edit

 

MODE

1

 

auto assemble edit

regenerated or not, during editing using the control panel of

 

 

2

 

manual

the VTR.

 

 

3

 

assemble & insert

0: When the VTR is used as a recorder for editing, the time

 

 

 

 

 

 

code generator automatically regenerates the time code

 

 

 

 

 

 

signal using the time code on the tape during assemble

 

 

 

 

 

 

or insert edit no matter what the setting of the [F6] (TCG

 

 

 

 

 

 

SOURCE) button in the TC menu is.

 

 

 

 

 

 

1: When the VTR is used as a recorder for ediing, the time

 

 

 

 

 

 

code generator automatically regenerates the time code

 

 

 

 

 

 

signal using time code of the time code generator on the

 

 

 

 

 

 

tape during assemble edit only, no matter what the

 

 

 

 

 

 

setting of the [F6] (TCG SOURCE) button in the TC

 

 

 

 

 

 

menu is.

 

 

 

 

 

 

2: The time code generator operates in accordance with the

 

 

 

 

 

 

setting of the [F6] (TCG SOURCE) button in the TC

 

 

 

 

 

 

menu, regardless of the operating mode of the VTR.

 

 

 

 

 

 

3: The time code generator regenerates the time code

 

 

 

 

 

 

signal in the off-tape LTC signal when edit preset is set

 

 

 

 

 

 

to ON (assemble/insert), regardless of local or remote

 

 

 

 

 

 

control.

Appendix