Error Messages
If an error occurs, the error message appears in the display window.
Error message | Cause | Countermeasure |
Please insert MS | No Memory Stick is inserted or the | Insert a Memory Stick and press the F2 key or F4 |
| inserted Memory Stick is not recognized. | key. |
|
|
|
Licence code error | The | Insert the Memory Stick supplied with the DASK- |
Please change Licence MS | inserted. | S704. |
|
|
|
No Space on MS[xxxxxxxx] | The memory capacity of the Memory | Change the Memory Stick to another one or delete |
Delete files or | Stick is not sufficient. | unnecessary data. (page 16) |
Change MS and Press F2 |
|
|
This file can’t be overwritten. Please select another file. OK?
You selected a memory number with data stored.
Select a memory number with | ” memory |
label and press the F4 key. |
|
This MS is newYou inserted a Memory Stick not named. Name the Memory Stick. (page 17) Press F4 and enter name of MS
Error indicators for the input digital signalWhen an error occurs on the input digital signal, the word SAMPLE or SETUP and an error indicator flash alternately. Simultaneously, the F1 key lights or flashes in red.
|
|
| MS:xxxxxxxx 24MB Available | |||
|
|
|
|
| Fs/Period=Fs/5.5sec | |
|
| Rehearsal | ||||
|
| Sampling |
| Repeat | =16 | |
|
| Compile |
| Input | =AD | |
|
|
|
|
| ||
|
| Change MS |
| Clock | =Internal 48.0 kHz | |
|
|
|
|
|
|
|
| SAMPLE |
|
|
| Enter | |
|
|
|
|
|
|
|
|
| Y |
| |
|
|
| Error indicator | |
|
| Sync | ||
|
|
| ||
Error indicator | Cause | Countermeasure | ||
|
|
| ||
Sync | When Word or AES (DI) sync is selected | Input an appropriate clock signal. | ||
| with Clock Sel, the clock signal frequency |
| ||
| is outside the range between |
| ||
| +8 % of the sampling frequency. |
| ||
|
|
| ||
Valid | Error of the validity bit | Input a correct digital signal. | ||
|
|
| ||
Slip | The input signal is not synchronized with | Input a correct digital signal. | ||
| the clock. |
| ||
|
|
| ||
CRC | Error of the CRC bit | Input a correct digital signal. | ||
|
|
| ||
Parity | Error of the parity bit | Input a correct digital signal. | ||
|
|
| ||
Bphase | Error of the | Input a correct digital signal. | ||
|
|
| ||
Unlock | The digital input signal is not locked. | Input a correct digital signal. | ||
|
|
|
|
|
Notes
•When operating with external sync, if you input a clock signal exceeding +8 % of the sampling frequency, the Sync error indicator is displayed. Even if you change the clock signal to a correct signal, the Slip error indicator may appear. In this case, disconnect the clock input, and reconnect it.
•The Sync error indicator may appear during rehearsal, sampling or compiling when the clock is switched. This is not a problem.
33(GB)