Note

When the camcorder is connected to a remote control unit and is being controlled remotely, the SHUTTER SPEED and several pages of the engineer-oriented menu (MEASUREMENT and DATA RESET pages) are not displayed. There are also some pages which are displayed but which you cannot use to change settings.

For information about the function of each page, refer to the relevant sections in this manual or the Maintenance Manual.

When changing the setup menu

4

You can configure the setup menu to display only the pages you need. To select pages, use the MENU SELECT page of the engineer-oriented menu. When using the engineer-oriented menu, switch the camcorder to engineer mode. Power off the camcorder, then hold down the rotary encoder and turn the power on again.

To revert to the user mode, turn the camcorder off and then on.

Engineer mode and user mode differ in the following ways.

Engineer mode: All the pages in the setup menu can be used. Data set with the menu is written to non-volatile memory and can be stored semi-permanently.

User mode: Only the pages selected in the engineer-mode MENU SELECT page can be used. Data set with the menu is written to non- volatile memory and can be stored semi-permanently.

After making settings and adjustments in engineer mode, configure the setup menu with the pages you use frequently so that you can access them quickly.

Refer to the Maintenance Manual for information about the MENU SELECT page.

Chapter 4 Adjustments and Settings for Recording 4-39