Menu items in the range 100 to 199, relating to the control panels (Continued)

Item number

Item name

Settings

 

 

 

 

 

 

 

 

 

107

REC INHIBIT LAMP

Select whether or not to flash the REC INHI indicator when the function menu

 

FLASHING

item RECINH is set to OFF and the record inhibit plug on the cassette is pressed

 

 

in.

 

 

OFF

: Do not flash the REC INHI indicator.

 

 

ON: Flash the REC INHI indicator.

 

 

 

 

 

 

 

 

 

108

AUTO EE SELECT

When a digital cassette is inserted and the function menu item PB/EE is set to

 

 

EE, select the VTR modes in which input video and audio signals are

 

 

automatically handled in E-E mode.

 

 

When an analog cassette is inserted, regardless of the function menu setting the

 

 

PB mode is always selected.

 

 

S/F/R

: In STOP/EJECT/F.FWD/REW modes

 

 

STOP: In STOP/EJECT modes

 

 

 

 

 

 

 

 

 

109

FORCED EE WHEN

During tape threading and unthreading, and when no cassette is inserted, select

 

TAPE UNTHREAD

whether the setting of the function menu item PB/EE controls the PB/EE setting

 

 

for output signals.

 

 

OFF: Control by the function menu item PB/EE

 

 

ON

: No control (always E-E signal)

 

 

 

 

 

 

 

 

 

111

TSO PLAY

Select whether or not to enable tape speed override mode.

 

 

DIS

: Disable tape speed override mode.

 

 

TSO: Enable tape speed override mode.

 

 

 

 

 

 

 

 

 

115

PHASE LOCK IN

Select whether or not to lock the capstan phase in 3 variable speed play mode

 

VARIABLE X3 (DVW-

when playing back a Betacam or Betacam SP cassette.

 

M2000/M2000P only)

OFF

: Do not lock.

 

 

ON: Lock.

 

 

 

 

 

 

 

 

 

116

JOG DIAL RESPONSE

Select the tape speed characteristics for the search dial rotation rate (VTR

 

 

commands).

 

 

TYPE1

: Tape speed varies linearly over the range –1 to +1.

 

 

TYPE2: Tape speed varies stepwise as shown in the figure belowa) over the

 

 

range –3 to +3. (Characterized by a zone around –1 and +1 where the tape

 

 

speed is independent of the search dial rotation rate)

 

 

TYPE3: Tape speed varies linearly over the range –3 to +3, as shown in the

 

 

figure belowb).

 

 

TYPE4: Tape speed varies stepwise as shown in the figure belowc) over the

 

 

range –2 to +2. (Characterized by a zone around –1 and +1 where the tape

 

 

speed is independent of the search dial rotation rate)

 

 

 

 

 

 

 

 

 

117

CONTROL PANEL

Select the control panel function when the PANEL SELECT switch on the switch

 

SELECTION

panel is set to REAR.

 

 

SW

: Only the control panel connected to the CONTROL PANEL connector on

 

 

the connector panel functions.

 

 

PARA: The control panels connected to the CONTROL PANEL connectors on

 

 

the switch panel and connector panel both function.

 

 

 

 

 

 

 

 

 

a)

 

 

 

 

 

b)

 

 

 

 

 

c)

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

Speed

 

 

 

 

 

Speed

 

 

TYPE 2

 

 

 

 

TYPE 3

 

 

 

 

 

TYPE 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+3

 

FWD

Rotation rate

 

 

 

+3

 

FWD

Rotation rate

+2

 

FWD

Rotation rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(reverse)

 

+1

 

 

 

 

 

 

 

 

 

+1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RVS

 

 

 

-1

FWD

 

 

RVS

 

 

 

 

FWD

RVS

 

-1

FWD

 

 

 

 

 

 

(forward)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-3

 

 

 

 

 

 

-3

 

 

 

 

 

-2

 

 

 

 

RVS

 

 

 

 

RVS

 

 

 

RVS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

Menus Setup 12 Chapter

Chapter 12 Setup Menus 12-9