Playback and Recording 4 Chapter
To synchronize the internal time code | 2 Perform the following settings in function menu | |||
generator to an external signal | page 1. | |||
|
|
| • When synchronizing to an external time code | |
Use this method to synchronize the time code | output (LTC) or the time code (VITC) in an input | |||
video signal: | ||||
generators of a number of VTRs, or to record the | ||||
TCG (F1): EXT | ||||
playback time code signal from an external VTR | ||||
TCG (F2): REGEN | ||||
without deterioration of the signal waveform. | ||||
VITC: ON (when recording VITC) | ||||
In this case the RUN and DF settings are ignored. You | ||||
TCR: LTC or VITC according as you are | ||||
can synchronize the internal time code generator to | ||||
synchronizing to LTC or VITC (If set to | ||||
either of the following external time codes. | ||||
AUTO, LTC is used.) | ||||
• The time code output (LTC) of an external time code | ||||
• When synchronizing to the time code (SMPTE | ||||
generator or external VTR connected to the TIME | ||||
RP188) in an SDI signal: | ||||
CODE IN connector of the unit | ||||
TCG (F1): RP188 | ||||
• The time code (VITC) present in a video signal input | ||||
TCG (F2), VITC, TCR: Any setting | ||||
to the unit |
|
| ||
|
|
| ||
• The time code (SMPTE RP188) present in an SDI | Note | |||
signal input to the unit |
| |||
| When the TCG (F1) is set to RP188, when settings | |||
|
|
| ||
To synchronize the internal time code generator to an | of the TCG (F1) and VID.IN conflict with each | |||
other, or when the input signal selected with the | ||||
external signal, use the following procedure. | ||||
VID.IN is not present, the TCG (F1) setting | ||||
|
|
| ||
|
|
| display flashes. | |
| Z |
| This starts the internal time code generator running | |
|
|
| in synchronization with the external time code | |
|
|
| generator. | |
|
|
| Once the internal time code generator is | |
|
|
| synchronized with the external time code | |
|
|
| generator, even if the external time code generator | |
|
|
| connection is removed, the internal time code | |
|
| 1,2 | generator continues to run. | |
IN | OUT |
| ||
| TIME CODE |
|
|
1
TIME CODE IN connector
1• When synchronizing to an external time code output (LTC):
Connect the time code output of the external time code generator or external VTR to the TIME CODE IN connector.
•When synchronizing to the time code (VITC) in an input video signal:
With the VID.IN in function menu HOME page, select an input video signal containing VITC.
•When synchronizing to the time code (SMPTE RP188) in an SDI signal:
With the VID.IN in function menu HOME page, select SDI.
Chapter 4 Recording and Playback |