Parts of Functions and Names 2 Chapter

2-2 Control Panel

1ACCESS indicator

2On/standby switch and indicator

3Remote control switch and NETWORK access indicator

4 KEY INHI switch

1 Time data settings section (see page 13)

2 Operating mode selection/menu setting section (see page 13)

3 Jog/shuttle control block (see page 14)

 

 

 

 

TC

COUNTER

 

SUB

THUMB

 

SHUTTLE

JOG

 

KEY INHI

 

 

SHIFT

 

 

 

 

 

CLIP

NAIL

 

 

 

NETWORK

ON

INT

PRESET

F-RUN SEL

HOLD

 

 

 

 

 

 

 

LOCAL

 

EXT

 

 

 

 

 

 

 

 

 

ACCESS

REMOTE

OFF

RP188

REGEN

R-RUN

 

 

CLIP

ESSENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL/CH-1

CH-2

CH-3

CH-4

 

 

MENU

MARK

 

 

 

METER

MONITOR

MENU

SET RESET

 

 

VARIABLE

 

 

 

 

 

 

 

 

 

 

 

 

SEL

SEL

 

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESET

 

 

 

 

 

 

 

 

 

 

 

 

PB

 

 

 

 

 

 

L/ST/R

SYSTEM

S.SEL

 

 

 

 

 

 

AUDIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

MARK1

 

 

 

 

 

 

 

 

 

 

 

 

PREV

PLAY

NEXT

STOP

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

OUT

 

TOP

F REV

F FWD

END

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MARK2

 

 

6 Arrow buttons (see page 16)

5Recording and playback control section (see page 16)

4Audio settings section (see page 15)

aACCESS indicator

This lights when the disc is accessed and when a file is opened by a FAM or FTP connections (see page 72).

If the on/standby switch is set to the 1 position while this indicator is lit, access to the disc is completed before the unit switches to the standby state.

Note

While the ACCESS indicator is lit, do not turn off the AC power switch, disconnect the power cord, or remove the battery. This could lead to a loss of data from the disc.

bOn/standby ("/1) switch and indicator

When the AC power switch on the rear panel is in the " position, or a battery is loaded, this switches the PDW-R1 between the operating (") and standby (1) states. When the switch is moved to the " position, the indicator lights. When the switch is moved to the 1 position, the indicator goes off.

When operating the PDW-R1 from an AC power supply, normally leave the AC power switch in the " position, and switch the PDW-R1 between the operating and standby states using the on/standby switch.

cRemote control switch and NETWORK access indicator

Different positions of the switch allow different operations as follows.

NETWORK: Enables access to the network. The indicator lights when an external network device is being accessed. In this state, operation from the control panel is not possible.

LOCAL: Enables operation from the control panel.

REMOTE: Enables remote control of the PDW-R1 from a device connected to the S400 (i.LINK) connector or REMOTE connector on the side panel.

Use extended menu item 214 “REMOTE INTERFACE” to select which of the connectors is used.

See 7-3-2 “Extended Menu Operations” (page 108) for more information about how to make extended menu settings.

dKEY INHI (key inhibit) switch

Setting this switch to ON lights the KEY INHI indicator and disables the switches and buttons that are set to “dis” with extended menu item 118 “KEY INHIBIT.”

12 2-2 Control Panel