Troubleshooting and Maintenance 8 Chapter

Message in time

Display

Description

Action

data display

condition a)

 

 

List Exists

on, limit, off

An attempt was made to edit a clip

Delete all clip lists.

 

 

referenced by sub clips.

See 5-3-2 “Deleting Clip Lists From a Disc”

 

 

 

 

 

 

(page 69).

 

 

 

 

Clip End!

on, limit, off

An attempt was made to edit across clip

Editing across multiple clips is not possible.

 

 

boundaries.

 

 

 

 

 

Recording

on, limit

More time than normal is required for

Wait until recording finishes.

 

 

recording processing, because

 

 

 

recording is being done while avoiding

 

 

 

defects on the disc.

 

 

 

 

 

a) With respect to setting of basic menu item 016

 

 

Alarms relating to audio and video signals

Message in time

Display

Description

Action

data display

condition a)

 

 

REF NON-STD

on, limit, off

A signal other than a standard reference

Input a standard reference video signal to

 

 

video signal was input to the REF

the REF VIDEO IN connector.

 

 

VIDEO IN connector.

 

 

 

 

 

No INPUT!

on

An attempt to record was made with no

Input a video signal, and select it.

 

 

input video signal.

 

 

 

 

 

VIN NON-STD

on

Recording is being done with a signal

Input a standard video signal to the VIDEO

 

 

other than a standard video signal input

IN connector.

 

 

to the VIDEO IN connector.

 

 

 

 

 

EMPHASIS!

on

An unsupported audio emphasis signal

This unit does not support “EMPHASIS

 

 

(“EMPHASIS ON” signal) was input.

ON” audio signals. Input “EMPHASIS OFF”

 

 

 

signal.

 

 

 

 

a) With respect to setting of basic menu item 016

 

 

Alarms relating to sensors and drives

Message in time

Display

Description

Action

data display

condition a)

 

 

 

 

HUMID!

on, limit, off

Condensation was detected in the unit.

 

See 8-2 “Condensation” (page 121).

 

 

 

 

 

FAN Stopped

on, limit, off

The motor of the main unit fan has

 

Contact your Sony service representative.

 

 

stopped.

 

 

 

 

 

 

 

Note

 

DR-FAN Stop

on, limit, off

The motor of a drive fan has stopped.

 

 

 

The unit will operate, but continued use in

 

 

 

 

High TEMP!

on, limit, off

Temperatures have risen within the unit.

 

 

this state will result in rising temperatures

 

 

 

 

in the unit or drive, with the risk of fire or

High TEMP!

on, limit, off

Temperatures have risen within a drive.

 

 

damage to the unit.

 

 

 

 

 

 

 

 

 

 

a) With respect to setting of basic menu item 016

 

 

 

 

130 8-4 Alarms