7-2 Basic Setup Menu
7-2-1 Items in the Basic Setup Menu
The basic menu items (excluding the items related to the digital hours meter) are listed in the following table.
•Item names are the names which appear in the video panel and on an external monitor, when the input signals to the monitor are the video signals output from the VIDEO OUT 2 (SUPER)/SDI OUT (SUPER) connector.
An abbreviated name appears in the time data display section when you press the NEXT button.
•The values in the Settings column are the values which appear in the time data display section. (The values may appear in a different format in the video panel and on an external monitor. In this case, the video panel values are shown in parentheses.) Underlined values are the factory defaults.
Menus 7 Chapter
Item number | Item name | Settings |
|
|
|
001 | PREROLL TIME | 0 s (0 sec)... 5 s (5 sec)... 30 s (30 sec): Set the preroll time to between 0 |
|
| and 30 seconds in steps of 1 second. |
|
| A preroll time of at least 5 seconds is recommended when using this |
|
| unit for editing. |
|
|
|
002 | CHARACTER | Adjust the horizontal screen position (as a hexadecimal value) of the text |
|
| information displayed on the monitor. a) |
|
| 00... 0A ...2A (525(U)/525(J) line modes) /00... 09 ...29 (625 line mode): |
|
| The hexadecimal value 00 is for the far left of the screen. Increasing the |
|
| value moves the position of the characters to the right. |
|
| a) Video panel and external monitor (when the input signals to the monitor are the |
|
| video signals output from the VIDEO OUT 2 (SUPER)/SDI OUT (SUPER) |
|
| connector) |
|
| Set this item by adjusting to the required position while viewing the monitor. |
|
|
|
003 | CHARACTER | Adjust the vertical screen position (as a hexadecimal value) of the text |
|
| information displayed on the monitor. a) |
|
| 00... 2E ...38 (525(U)/525(J) line modes)/00... 37 ...43 (625 line mode): |
|
| The hexadecimal value 00 is for the top of the screen. Increasing the |
|
| value lowers the position of the characters. |
|
| a) Video panel and external monitor (when the input signals to the monitor are the |
|
| video signals output from the VIDEO OUT 2 (SUPER)/SDI OUT (SUPER) |
|
| connector) |
|
| Set this item by adjusting to the required position while viewing the monitor. |
|
|
|
005 | DISPLAY INFORMATION | Determine the kind of text information to be displayed on the monitor. a) |
| SELECT | off (display off): Do not output text information. |
|
| T&sta (time data & status) : Time data and the units status. |
|
| T&UB (time data & UB): Time data and user bit data. (When UB (user bit |
|
| data) is selected with the COUNTER SEL button, the user bit data and |
|
| time data arranged in that order are displayed.) |
|
| T&CNT (time data & CNT): Time data and counter count. (When |
|
| COUNTER is selected with the COUNTER SEL button, the counter |
|
| count and time data arranged in that order are displayed.) |
|
| T&T (time data & time data): Time data and time code (TC or VITC). |
|
| T&clp (time data & clip name): Time code and clip name |
|
| time (time data only): Time data only. |
|
| a) Video panel and external monitor (when the input signals to the monitor are the |
|
| video signals output from the VIDEO OUT 2 (SUPER)/SDI OUT (SUPER) |
|
| connector) |
|
|
|
90