Menu items in the 200s, relating to the remote control interface

Item number

Item name

 

Settings

 

 

 

 

 

 

258

LIVE LOGGING

 

Enable or disable the live logging function when using the PDZ-1 Proxy

 

 

 

Browsing Software.

 

 

 

off: Disable.

 

 

 

on: Enable.

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

 

During

live logging, regardless of the settings of the switches (INT/EXT/

 

 

 

RP188, PRESET/REGEN, and F-RUN/R-RUN) in the time data settings

 

 

 

section, the internal time code generator always runs in free run mode.

 

 

 

Time code cannot be recorded in internal preset mode.

 

 

 

 

 

 

 

Menu items in the 300s, relating to editing operations

 

 

 

 

Item number

Item name

Settings

 

 

 

 

 

 

308

SELECTION OF STD/NON-STD

 

Select the STD or NON-STD mode in accordance with a composite

 

 

FOR COMPOSITE VIDEO IN

 

video or S-video input.

 

 

 

 

STD (forced STD): The STD mode is always used (forced STD mode).

 

 

 

 

N-STD (forced non-STD): Use this setting when the input video signal is

 

 

 

 

unstable (forced NON-STD mode).

 

 

 

 

 

 

 

 

 

 

Note

 

 

 

When

using a VCR with no built-in time base corrector (e.g. a home-use

 

 

 

 

VHS-system VCR), select N-STD.

 

 

 

 

 

 

310

REC INHIBIT

 

Select whether recording is inhibited.

 

 

 

 

off: Do not inhibit recording.

 

 

 

 

on: Inhibit recording.

 

 

 

 

 

 

320

DIGITAL AUDIO PB PROCESS ON

 

Select the treatment of audio playback at edit points.

 

 

EDIT POINT

 

cut: Carry out a cut (possibly resulting in audio discontinuities at the edit

 

 

 

 

point).

 

 

 

 

fade: Fade out and fade in.

 

 

 

 

 

 

335

OUTPUT REFERENCE SEL

 

Select the reference signal of this unit.

 

 

 

 

ref (ref. video): Use the signal input to the REF VIDEO IN connector as

 

 

 

 

the reference signal.

 

 

 

 

auto: According to the operation mode, automatically select either the

 

 

 

 

signal input to the REF VIDEO IN connector or the input video signal

 

 

 

 

selected with the VIDEO INPUT SEL button as the reference signal.

 

 

 

 

For more details, see the following item “External synchronization to

 

 

 

 

reference signal generators” (page 100).

 

 

 

 

The input digital audio signals and video signals must be synchronized

 

 

 

 

with the reference signal input to the REF VIDEO IN connector.

 

 

 

 

 

 

 

 

Menus 7 Chapter

7-3 Extended Menu 99