SpectraLink Corporation | Link WTS Installation and Operation |
Switch Interface | Line LEDs | MCU Type | Notes |
|
|
|
|
|
|
|
|
Analog | 1 | SCA | The SCA will only support Analog |
|
|
|
|
Comdial | 3 | SCU |
|
|
|
|
|
DEFINITY - 2 wire | 1,4 | SCU |
|
|
|
|
|
DEFINITY - 4 wire | 1,5 | SCF |
|
|
|
|
|
Executone | 2,5 | SCB |
|
|
|
|
|
Fujitsu | 2,4 | SCU |
|
|
|
|
|
2,3,4 | SCU |
| |
|
|
|
|
Meridian | 1,2 | SCU |
|
|
|
|
|
Merlin Legend | 1,3 | SCF |
|
|
|
|
|
Mitel | 1,2,3 | SCX | The SCX will only support Mitel |
|
|
|
|
NEC | 1,2,4 | SCU |
|
|
|
|
|
Norstar | 2 | SCU |
|
|
|
|
|
Panasonic | 5 | SCP |
|
|
|
|
|
Siemens / Rolm | 4 | SCU |
|
|
|
|
|
Toshiba | 2,3 |
|
|
|
|
|
|
Unconfigured | 1 through 8 |
|
|
|
|
|
|
6.Move the Mode Switch back to NORMAL .
7.The MCU will cycle through diagnostic testing. When the system is ready for use, the error LED should be off, and the LED for the MCU Number
If the LED for the MCU ID does not light, or if an MCU ID is duplicated, there is most likely a problem with the IPC cabling. If the system displays an error refer to 8.1 Troubleshoot Error Codes.
8.If you select a switch type that is not supported by the MCU type, the system will alarm. The Error LED will flash along with Status LEDs 4 and 5. For example, this alarm will display if you assign switch type NEC to an
If this alarm displays, use the table above to verify that your MCU type supports the selected switch type. If you need to change the switch type, repeat steps 2 through 6.
Part Number: | Page 22 |