| SpectraLink Corporation | Link WTS Installation and Operation |
| |
|
|
|
|
|
| Status | Description | Action |
|
| LEDs |
| ||
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| 4 | IPC problem. | Check IPC cabling by disconnecting and |
|
|
|
| reconnecting the MCUs. Connect the Male |
|
|
|
|
| |
|
|
| demarcation block to the designated |
|
|
|
| connector (A or B) on each MCU. Secure |
|
|
|
| cables using the keeper. |
|
|
|
| If the error still occurs try using a different |
|
|
|
| IPC cable. Replace MCU if the problem still |
|
|
|
| occurs. |
|
|
|
|
|
|
| 4,5 | The switch type selected is not | Verify that the switch type selected is correct. |
|
|
| supported by this MCU. | If the type is incorrect, repeat the steps to |
|
|
|
| select a new switch type. See section 5.3.5. |
|
|
|
|
|
|
| 1,4 | The operator is trying to register a | Return mode switch to the NORM position. |
|
|
| Wireless Telephone or place an |
|
|
|
| admin call on an MCU with no |
|
|
|
| phone lines. |
|
|
|
|
|
|
|
| 2,4 | The MCU was powered on with the | Turn off the MCU, place the mode switch to |
|
|
| mode switch in the wrong position. | the NORM position and turn back on. |
|
|
|
|
|
|
| 3,4 | Configurations on a | Erase the configuration in the MCU with |
|
|
| installation do not match in each of | incorrect configuration definitions (probably |
|
|
| the units. | the MCU that was just added.) To erase the |
|
|
| Most likely to occur when an MCU | configuration, refer to Replace an MCU. |
|
|
| was just added to the system. | Note: Do not erase the configurations in all |
|
|
|
| the MCUs. In multiple MCU installations the |
|
|
|
| Wireless Telephone registration information |
|
|
|
| is shared among the MCUs. This allows you |
|
|
|
| to replace an MCU without |
|
|
|
| the Wireless Telephones. |
|
|
|
|
|
|
| 1,3,4 | REGISTER or ADMIN mode | Only one mode switch can be in ADMIN or |
|
|
| selected on more than one MCU at | REGISTER at a time. Check the MCUs and |
|
|
| the same time. | take one of them out of REGISTER or |
|
|
|
| ADMIN mode. |
|
|
|
|
|
|
| 2,3,4 | The MCU was powered on with the | Turn off the unit, place the mode switch to |
|
|
| mode switch in the wrong position. | the NORM position and turn back on. |
|
|
|
|
|
|
| 1,2,3,4 | Internal problem with the MCU. | Contact SpectraLink Customer Service for |
|
|
|
| technical support. |
|
|
|
|
|
|
| 1,5 | The MCU was powered on with the | Turn off the MCU, place the mode switch in |
|
|
| mode switch in the wrong position. | the NORM position and turn back on.. |
|
|
| A possible Base Station failure has | Check to see if the system was powered on |
|
|
| been detected. A Base Station that | with the switch in the wrong position. If not, |
|
|
| had previously been heard by | contact SpectraLink Customer Service. |
|
|
| another Base Station can no longer |
|
|
|
| be heard. |
|
|
|
|
|
|
|
Part Number: | Page 32 |