Sun Microsystems Sun Fire V100 manual OpenBoot Diagnostics, Type

Models: Sun Fire V100

1 146
Download 146 pages 47.17 Kb
Page 119
Image 119
OpenBoot Diagnostics

OpenBoot Diagnostics

Like POST diagnostics, OpenBoot Diagnostics can be run if the diag-switch?variable is set to true.

You can also run OpenBoot Diagnostics interactively and select which tests you want it to perform. To do so, follow the steps below from the ok prompt.

1. Type:

ok setenv diag-switch? true ok setenv auto-boot? false ok reset-all

2. Type:

ok obdiag

This displays the OpenBoot Diagnostics menu:

 

 

obdiag

 

 

1

SUNW,lomh@0,8010

2

ethernet@5

3

ethernet@c

4

i2c-nvram@0,a0

5

ide@d

6

pmu@3

7

serial@0,2e8

8

serial@0,3f8

9

usb@a

Commands: test test-all except help what printenvs setenv versions

exit

 

 

 

 

 

 

 

 

FIGURE 10-1 The obdiag Menu

 

 

 

The tests are described in TABLE 10-1. Note the number that corresponds to the test you want to perform, and use it with the test command. For example, to run a test on the primary Ethernet port, type:

obdiag>

test 3

 

Hit

the

spacebar to interrupt testing

 

Testing

/pci@1f,0/ethernet@c

passed

Hit

any

key to return to the main menu.

 

 

 

 

 

Chapter 10 Troubleshooting 101

Page 119
Image 119
Sun Microsystems Sun Fire V100 manual OpenBoot Diagnostics, Type