Electromagnetic compatibility

Immunity: The server conforms to EN55024.

Emissions: The server conforms to EN55022 Class A and FCC Class A.

Safety

The system conforms to UL 1950 (3rd edition), EN60950

Operating Power Statistics

TABLE A-2Operating Power Statistics

Maximum operating current

1.3A @ 100 VAC

 

 

Typical operating current

See “Calculating Power Consumption” on

 

page 118

Maximum in-rush

40A peak at 115V 25˚C

current (cold start)*

 

Maximum in-rush

100A peak at 115V 25˚C

current (warm start, or upon a restart 20 to

 

200 msecs after power has been removed*)

 

Operating input voltage range

90 to 264 Vrms

Voltage frequency range

47 to 63 Hz

Power factor

0.9 to 0.99

Maximum volt-ampere rating

130 VA

BTU/hr

500 MHz processor: 148 (min), 280 (max).

 

 

*The in-rush current decays to the normal operating current in less than 200 msecs.

Caution The power supply continues to regulate all outputs for at least 17 ms after AC power is removed.

Note Logic ground and chassis ground are connected internally.

Appendix A Physical and Environmental Specifications 117