Configuring the LOM Device Driver

The full list of parameters you can set in this file is given in TABLE B-1.

TABLE B-1LOM Configuration File Parameters

Field

Format

Default

Effect

 

 

 

 

wdog_reset=

Boolean

0

Causes LOM to reset the server

 

0=FALSE

 

after a watchdog timeout.

 

1=TRUE

 

Setting this to 1 is equivalent to

 

 

 

using the lom -R on command

 

 

 

described in Chapter 6.

wdog_alarm3=

Boolean

0

Turns on software alarm 3 when

 

0=FALSE

 

the LOM watchdog times out.

 

1=TRUE

 

Setting this to 1 is equivalent to

 

 

 

using the lom -A on,3

 

 

 

command described in

 

 

 

Chapter 6.

serial_events=

0=OFF

2

Causes LOM to report events

 

1=ON

 

over the serial connection.

 

2=ON

 

Setting this parameter to 0

 

WHEN

 

means that no events will be

 

DRIVER

 

reported over the serial

 

NOT

 

connection. Setting it to 1 means

 

LOADED

 

that events will be reported

 

 

 

over the serial connection as

 

 

 

well as to syslogd; this is

 

 

 

equivalent to lom -E on. If

you have dedicated the Serial A/LOM port to LOM, you need to set this parameter to 1. It ensures that you receive all event reports at the terminal you have connected to Serial A/ LOM. Finally, setting the parameter to 2 means that events will be reported over the serial connection but only when the driver is not running (when it is running they will be reported to syslogd, although Fatal and Warning messages will still go to Serial A/LOM).

Appendix B Configuring LOM Driver 121

Page 139
Image 139
Sun Microsystems Sun Fire V100 manual Configuring the LOM Device Driver, Table B-1LOM Configuration File Parameters