Sun Microsystems Sun Fire V100 manual c. Click OK 6. In the Connect To window a. Click Edit

Models: Sun Fire V100

1 146
Download 146 pages 47.17 Kb
Page 46
Image 46
c.Click OK.

c.Click OK.

6.In the Connect To window:

a.Click Edit.

b.Click Connect Using.

c.In the drop-down menu, click Direct to COM1.

Note If you connected the DB-9 adaptor to a port other than COM1 on your PC or laptop in Step 3, choose the appropriate option from the list in the drop-down menu.

d. Click OK.

7.In the COM1 Properties window:

a.Change the Bits Per Second value to 9600.

b.Set Flow Control to Xon/Xoff.

The correct values for all settings in this window are as shown below.

Property

Setting

 

 

Bits Per Second

9600

Data Bits

8

Parity

None

Stop Bits

1

Flow Control

Xon/Xoff

 

 

c.Click OK.

The lom> prompt now appears in the Windows Hyperterminal. For information about how to power on and configure the server, go to “Powering On and Configuring the Server” on page 34.

28 Sun Fire V100 User’s Guide • December 2001

Page 46
Image 46