Texas Instruments TMS320DM36X manual Transmit Teardown Register Txteardown, Txtdnch

Models: TMS320DM36X

1 134
Download 134 pages 23.68 Kb
Page 87
Image 87

www.ti.com

Ethernet Media Access Controller (EMAC) Registers

5.3Transmit Teardown Register (TXTEARDOWN)

The transmit teardown register (TXTEARDOWN) is shown in Figure 42 and described in Table 40.

Figure 42. Transmit Teardown Register (TXTEARDOWN)

31

 

 

16

 

Reserved

 

 

 

 

 

 

 

R-0

 

 

15

3

2

0

 

 

 

 

Reserved

 

 

TXTDNCH

 

 

 

 

R-0

 

 

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n= value after reset

Table 40. Transmit Teardown Register (TXTEARDOWN) Field Descriptions

Bit

Field

Value

Description

 

 

 

 

31-3

Reserved

0

Reserved

 

 

 

 

2-0

TXTDNCH

0-7h

Transmit teardown channel. The transmit channel teardown is commanded by writing the encoded

 

 

 

value of the transmit channel to be torn down. The teardown register is read as 0.

 

 

0

Teardown transmit channel 0

 

 

1h

Teardown transmit channel 1

 

 

2h

Teardown transmit channel 2

 

 

3h

Teardown transmit channel 3

 

 

4h

Teardown transmit channel 4

 

 

5h

Teardown transmit channel 5

 

 

6h

Teardown transmit channel 6

 

 

7h

Teardown transmit channel 7

 

 

 

 

SPRUFI5B –March 2009 –Revised December 2010 Ethernet Media Access Controller (EMAC)/Management Data Input/Output 87