Texas Instruments TMS320F20x/F24x DSP Preliminary, Assembly Source Listings and Program Examples

Models: TMS320F20x/F24x DSP

1 108
Download 108 pages 2.5 Kb
Page 93
Image 93
A-41

PRELIMINARY

Sample Assembly Code to Erase and Reprogram the TMS320F240

;**Variables included from flash algorithms.

.include ºsvar20.hº

;Variable declarations

.ref

GCLR

;References clear algo.

.ref

GPGMJ

;References program algo.

.ref

GERS

;References erase algo.

.ref

FLWS

;References flash±write algo.

;**Parameters used by flash algorithms.

.def

PRG_bufaddr, PRG_paddr

.def

PRG_length, PARMS

.def SEG_ST,SEG_END,PROTECT ;**F240 Register definitions

RTICR

.set

07027h

;RTI Control Register

WDCR

.set

07029h

;WD Control Register

CKCR0

.set

0702Bh

;Clock Control Register 0

CKCR1

.set

0702Dh

;Clock Control Register 1

SYSSR

.set

0701Ah

;System Module Status Register

DP_PF1

.set

224

;page 1 of peripheral file

 

 

 

;(7000h/80h)

*************************************************************

VARS: .usect ºPRG_dataº,16 ;This is an uninitialized data

*

;section required by the standard *

;flash algos for temporary

*

;variables. Pointers to this

*

;space are hardcoded in SVAR20.H, *

;and variables are init'd at

*

;run time.

*

*************************************************************

PARMS: .usect ºPRG_parmº,10 ;This is an uninitialized data

*

;section that is used for

*

;temporary variables and for

*

;passing parameters to the flash

*

;algorithms.

*

*************************************************************

PROTECT .set PARMS ;Segment enable bits.*

**************************************************************

*****Parameters needed for Programming algorithm. ***

*************************************************************

PRG_bufaddr

.set

PARMS+1

;Addr of buffer for pgm data. *

PRG_paddr

.set

PARMS+2

;1st flash addr to program.

*

PRG_length

.set

PARMS+3

;Length of block to program.

*

*************************************************************

***Parameters needed for CLEAR, ERASE, and FLW algorithms. **

*************************************************************

SEG_ST

.set

PARMS+4

;Segment

start address.

*

SEG_END

.set

PARMS+5

;Segment

end address.

*

*************************************************************

****Other misc variables.****

*************************************************************

ERS_COUNT .set PARMS+6 ;Used for erase fail count. *

*************************************************************

.text

*************************************************************

**

First, initialize the key F240 registers for use with

*

**

the EVM.

*

*************************************************************

PRELIMINARY

Assembly Source Listings and Program Examples

A-41

Page 93
Image 93
Texas Instruments TMS320F20x/F24x DSP manual Preliminary, Sample Assembly Code to Erase and Reprogram the TMS320F240, A-41