Texas Instruments TVP5147M1PFP manual Status 2 Register, AGC Gain Status Register, Signal present

Models: TVP5147M1PFP

1 100
Download 100 pages 24.7 Kb
Page 55
Image 55
2.11.35 Status 2 Register

Functional Description

2.11.35 Status 2 Register

Subaddress

3Bh

Read only

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

Signal present

Weak signal detection

PAL switch polarity

Field sequence status

Color killed

Macrovision detection [2:0]

Signal present detection:

0 = Signal not present

1 = Signal present

Weak signal detection:

0 = No weak signal

1 = Weak signal mode

PAL switch polarity of first line of odd field:

0 = PAL switch is zero.

1 = PAL switch is one.

Field sequence status:

0 = Even field

1 = Odd field

Color killed:

0 = Color killer not active

1 = Color killer activated

Macrovision detection [2:0]:

000 = No copy protection

001 = AGC pulses/pseudo syncs present (type 1)

010 = 2-line color stripe only present

011 = AGC pulses/pseudo syncs and 2-line color stripe present (type 2) 100 = Reserved

101 = Reserved

110 = 4-line color stripe only present

111 = AGC pulses/pseudo syncs and 4-line color stripe present (type 3)

2.11.36 AGC Gain Status Register

Subaddress

3Ch−3Dh

Read only

Subaddress

7

6

5

4

 

3

2

1

0

 

 

 

 

 

 

 

 

 

 

3Ch

 

 

 

 

Fine gain [7:0]

 

 

 

 

 

 

 

 

 

 

 

3Dh

 

Coarse gain [3:0]

 

 

 

Fine gain [11:8]

 

Fine gain [11:0]: This register provides the fine gain value of sync channel.

1111 1111 1111 = 1.9995

1000 0000 0000 = 1

0010 0000 0000 = 0.5

Coarse gain [3:0]: This register provides the coarse gain value of sync channel.

1111 = 2

0101 = 1

0000 = 0.5

These AGC gain status registers are updated automatically by the TVP5147M1 decoder with AGC on. In manual gain control mode, these register values are not updated by the TVP5147M1 decoder.