2.12.10 Analog Output Control 2 Register

Functional Description

2.12.10 Analog Output Control 2 Register

Subaddress

 

A0 005Eh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

B2h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

6

 

5

4

3

2

 

1

0

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

Reserved

 

Input Select [1:0]

 

 

Gain [3:0]

 

Analog input select [1:0]: These bits are effective when manual input select bit is set to 1 at subaddress 7Fh, bit 1.

00 = CH1 selected

01 = CH2 selected

10 = CH3 selected

11= CH4 selected (default)

Analog output PGA gain [3:0]: These bits are effective when analog output AGC is set to 1 at subaddress 7Fh, bit 2.

Gain [3:0]

Mode 1

0000

=

1.30

0001

=

1.56

0010 = (default)

1.82

0011 =

2.08

0100

=

2.34

0101

=

2.60

0110 =

2.86

0111 =

3.12

0000

=

3.38

0001

=

3.64

0010

=

3.90

0011 =

4.16

0100

=

4.42

0101

=

4.68

0110 =

4.94

0111 =

5.20

2.12.11

Interrupt Configuration Register

 

 

 

 

 

Subaddress

 

 

B0 0060h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

6

 

5

4

3

2

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

Polarity

 

Reserved

Polarity: Interrupt terminal polarity

0 = Active high (default)

1 = Active low