Contents
G8000 Series
Page
G8000 Series
Qualified Personnel only
Uninterruptible Power System UPS
Toshiba Customer Support Center
Purpose
Toshiba’s Customer Support Center
Toshiba International Corporation
Table of Contents
Terminal Blocks, Terminal Bus, and Power Cables 11.3
Introduction
Prohibited Symbol indicates do not take action
General Safety Instructions
Symbols
Signal Words
Qualified Personnel
Important Safety Instructions
Factory Authorized Personnel
Safety Precautions
Disclaimer
Transporting/Unpacking
General Maintenance
Keep the area arround the UPS clean
Do not tilt the UPS more than 10 from upright position
Do not transport, move, store, or place the UPS on its side
Avoid vibration or shock exceeding 0.5G
Inspection/Storage
Keep the Specified Clearance around the UPS
Installation Precautions
Install the UPS in a controlled environment
Do not install the UPS where water may fall on it
Do not block air vents
Installation Precautions
Environment standard
Page
Connect only one 1 ground wire to the earth ground terminal
Wiring/Connection
Perform wiring and connections with correct polarity
Follow the torque criteria for tightening screws
For 100 and 150 kVA
GND
150kVA UPS Warning Labels
Weight and Dimensions
Model Unit Shipping
150kVA UPS Exterior Dimensions Inches
Transporting
Do not expose the unit to vibration or shock exceeding 0.5G
Transporting By Crane
8.5 show examples of acceptable and unacceptable operations
Transporting By Forklift
Transporting UPS by Forklift
Operating Precautions
Storage/Operating Environment
Page
Qualified Personnel shall
Maintenance Precautions
Qualified Personnel only
Do not open or mutilate the batteries
Disposal
Do not dispose of the batteries in a fire
Installation
Unpacking
UPS Clearance
Anchor Bolts
UPS Wiring
Breaker
Terminal Blocks, Terminal Bus, and Power Cables
AC Input Bypass Input AC Output Battery
Block Number Cable Size Tightening Torque 100 KVA 150 KVA
External Breakers
Bottom Cable Knockout Plates 100 kVA
Grounding Wire
Be sure to ground the UPS as specified
Control Wires
Signal Name Operation
Connection Between UPS, Battery Cabinet & Bypass Breaker
Grounding Configuration
Jumper Cable Between the Neutral Terminal & Ground BUS
Mechanical Specification
UPS Specifications
General Specification
Rated Capacity 150kVA
Electrical Specification
Do not open the front cover
Operator Interface
UPS may not respond if the button press is too short
Key-Switch and Buttons
Graphic display Panel KEY-SWITCH/OPERATING Buttons
13.2 LCD/LED Indicators
Graphic display Panel LCD/LED INDICAtors
LCD Indicators
Name Description
Volt Freq .0Hz
Normal Display
AC-VO AC- I O 50%
50%
DC-V BATT-V BATT- I 0A
AC I/P-V Freq .0Hz
BYP I/P-V Freq .0Hz
32TIM
Fault Display
09-09-06
LCD Scroll
Abbreveations
Epo and Control Power supply operating switches
Operating the UPS
Perform the pre-operational check before operating the UPS
Operation Types
Pre-operational Check
Startup Procedures
Step
AC Vo 208 AC Io 50%
Switch Power Supply UPS→Bypass
Bypass LED is on
Stop
Complete Shutdown
DC-V 0 BATT-V 0 BATT-I 0 a
Changing Between Float Charge and Equalize Charge
Make sure that the Float Charge LED is on
Make sure that the Batt FAULT1 warning goes away
Types of Errors
Troubleshooting
Emergency Power Off EPO
Faults and Warnings Data Screen
09-09-06
LCD Fault & Warning Displays
Fault Display
Fault Messages
Over Heat
AC O/P UV
LCD Scroll w/ faults or warnings
Button functions
Do not attempt to modify or relocate the UPS
Contact Toshiba in the event of malfunction or fault
Restoring UPS Operation
Do not open the front and/or rear panels