6 Warning Labels
Below are representative warning labels and their location on the UPS. Exterior Handling labels shown in section 4.3, Transporting/Unpacking, are in the manual packet, and attached to the UPS shipping covering and shipping pallet.
ATTENTION
Make sure all the warning labels are installed in the appropriate locations.
If a label is missing or illegible, contact Toshiba Customer Support Center or an authorized representative.
(A) – 48082
DANGER
AC VOLTAGE
This UpS receives power from more than one source. Disconnect all AC sources before performing any service or testing inside this unit
48082
(C) – 59940 for 100 and 150 kVA
(B) – 40308
DANGER
HAZARDOUS VOLTAGES Hazardous voltages are used in the operation
of this equipment and could cause severe personal injury or loss of life.
The following precautions should be observed to reduce the risk of injury or death.
only qualified technicians familiar with this equipment and the information supplied with it should be permitted to install and operate this equipment.
Installation of electrical equipment must be done in accordance with National electrical Code and any other state or local codes. proper grounding and conductor sizing must be installed for safe operation.
During operation, keep all covers in place and cabinet doors shut.
when performing visual inspections and maintenance, if possible, be sure the UpS is turned off and the incoming AC feed is turned off and locked out.
The UPS and Battery Cabinet will have hazardous voltages present even after the AC feed is turned off.
If it is necessary to make measurements with the power on, do not touch any electrical connection points. remove all jewelry from wrists and fingers. make sure test equipment is in good, safe operating condition.
while servicing, stand on some type of insulation, and be sure not to be grounded.
Follow the safety instructions given in the equipment manual carefully and observe all danger, warning and caution notices.
40308
(D) – 40830
WA R N I N G
CRITICAL FUSE SIZING
Incorrect fuse replacement size may result in fire or inadequate equipment protection.
replace only with same type
and rating of fuse. | PN 40830 |
|
14 | G8000 Series with Isolated Output Installation and Operation Manual |