The amount total (whole package price) will be 100 so that the unit price of individual split package of PLU3 is arranged automatically.

4. PROGRAMMING OPERATIONS

EO1-11149

 

4.7 PLU Table Programming (Submode 4)

 

 

6. Status Code and Scale Status Code are as the tables below show. Status Code Table (Default: 0)

Item

Code

0

1

2

3

4

5

6

 

7

Negative

 

 

O

 

O

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

 

HI-CONE Status

 

 

 

O

O

 

 

O

 

O

 

 

 

 

 

 

 

 

 

 

 

M & M Table

 

 

 

 

 

 

 

O

 

O

 

 

 

 

 

 

 

 

 

 

By HI-CONE Status setting, a PLU will be programmed for commodities in a package.

 

Scale Status Code Table (Default: 0)

 

 

 

 

 

 

 

 

 

 

Item

Code

0

1

2

3

4

5

6

 

7

Scale Status

 

 

O

 

O

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

Tare 2 (Manual Tare) Entry Compulsion

 

 

 

O

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

Food Stamp Symbol is printed. (NOTE 12)

 

 

 

 

O

O

O

 

O

 

 

 

 

 

 

 

 

 

 

 

7.HALO digit/LALO digit

HALO (High Amount to be Locked Out)

LALO (Low Amount to be Locked Out)

0: No limit

 

0: No limit

 

1: 1 digit

(0 to 9)

1: 1 digit

(1 to 9999999)

2: 2 digits

(0 to 99)

2: 2 digits

(10 to 9999999)

3: 3 digits

(0 to 999)

3: 3 digits

(100 to 9999999)

4: 4 digits

(0 to 9999)

4: 4 digits

(1000 to 9999999)

5: 5 digits

(0 to 99999)

5: 5 digits

(10000 to 9999999)

6: 6 digits

(0 to 999999)

6: 6 digits

(100000 to 9999999)

7: 7 digits

(0 to 9999999)

7: 7 digits

(1000000 to 9999999)

8.“00” indicates that no Link PLU exists. This setting is applied to the PLUs without M & M Table setting. Up to 99 can be entered, however, the Numbers 51 to 99 indicate that no Link PLU exists.

9.M & M Group

Item

PLU

PLU1

PLU2

PLU3

Whole Package Price

 

100

100

100

 

 

 

 

 

Whole Package Quantity

 

3

3

3

 

 

 

 

Unit Price of Individual Split Package

40

40

40

 

 

 

 

In case PLU1 to PLU3 are set in different M & M Groups respectively:

 

1 [SPLIT PRICE] 1 [PLU] --- 40

 

 

 

 

1 [SPLIT PRICE] 2 [PLU] --- 40

The amount total will be 120.

 

1 [SPLIT PRICE] 3 [PLU] --- 40

 

 

 

 

In case PLU1 to PLU3 are set in the same M & M Group: 1 [SPLIT PRICE] 1 [PLU] --- 40

1 [SPLIT PRICE] 2 [PLU] --- 40

1 [SPLIT PRICE] 3 [PLU] --- 20

10.The Tare Table can be programmed in 4.23 Tare Table Setting (Submode 56).

4-16

Page 127
Image 127
Toshiba MA-1535-2 owner manual Split Price 1 PLU Split Price 2 PLU