4. PROGRAMMING OPERATIONS |
4.7 PLU Table Programming (Submode 4)
4.7 PLU Table Programming (Submode 4)
CONDITION
OPERATION
To program new PLUs or to change any programmed contents of PLUs except the following case: Anytime outside a sale
To change the linked Department of a PLU with sales data not zero: After PLU Reset
Control Lock: SET
Repeat for other PLUs.
04[#/NS]
PLU Code [#/NS]
Max. 14 digits (Free code)
(See NOTE 2 on the next page.)
Source Code or
| 01: PLU Name |
|
|
|
|
|
| [AT/TL] |
| |||||||||
|
|
|
|
|
| Character entry |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
| Max. 18 characters |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| (See NOTE 3 on the next page.) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 02: Preset Price/Unit Price of Whole Package for | *1 |
|
|
|
| [AT/TL] |
|
| |||||||||
|
|
|
|
|
| Preset Price or Unit Price of Whole Package |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| Max. 8 digits | Max. 8 digits |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| (0 to 99999999) | (0 to 99999999) |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 03: 2nd Preset Price/Unit Price of Indiv. Split Package | *1 |
|
| [AT/TL] |
| ||||||||||||
|
|
|
|
|
| 2nd Preset Price or Unit Price of Indiv. Split Package |
|
|
| |||||||||
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
| Max. 8 digits | Max. 8 digits |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| (0 to 99999999) | (0 to 99999999) |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 04: 3rd Preset Price/Whole Package Quantity for | *1 |
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| [AT/TL] |
| ||
|
|
|
|
|
| 3rd Preset Price or Whole Package Quantity |
|
|
| |||||||||
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
| Max. 8 digits | Max. 8 digits |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| (0 to 99999999) | (0 to 99999999) |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 05: Tax Status |
|
|
|
|
|
| [AT/TL] |
|
| ||||||||
|
|
|
|
|
| Tax Status |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Max. 5 digits |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| (See NOTE 4 on the next page.) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 06: PLU Group Number |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| PLU Group Number |
|
|
|
|
|
| [AT/TL] |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| 2 digits (01 to 99) |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 07: Link Department |
|
|
|
|
|
| [AT/TL] | ||||||||||
|
|
|
|
|
| Department Code |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
2 digits (01 to 99)
(See NOTE 5 on the next page.)
08: Status Code/Scale Status Code *1,*2
Status Code Scale Status Code [AT/TL]
| 1 digit | 1 digit | |
| (See NOTE 6 on the next page.) | ||
|
| ||
09: High Amount Limit digit/Low Amount Limit digit | |||
| HALO LALO |
| [AT/TL] |
|
| ||
| 1 digit 1 digit |
|
|
(See NOTE 7 on the next page.)
10: Link PLU No. 1/M & M Group Number
*2
Link PLU No. 1 or M & M Group No.
2 digits (01 to 50) | 2 digits (01 to 99) |
(See NOTE 8 on the next page.) | (See NOTE 9 on the next page.) |
*1: This setting is exclusive to the PLU allocated
*2: This setting is exclusive to the PLU allocated M & M Table in the Status Code setting.
[AT/TL]
A